KME LPG reducer SILVER S6 (160KW) incl. solenoid valve
KME LPG reducer SILVER S6 (160KW) incl. solenoid valve
KME LPG reducer SILVER S6 (160KW) incl. solenoid valve
KME LPG reducer SILVER S6 (160KW) incl. solenoid valve

KME LPG reducer SILVER S6 (160KW) incl. solenoid valve

Article no.: 101716
Manufacturer: KME

Offer is exclusively for commercial customers. Prices are only visible after login.

  • Product description
  • Spare parts

Homologation number E8 67R-01 3949

Technical data KME SILVER S6 reducer

Evaporator material
Cast aluminium
weight
1.11 kg
Dimensions
119x88 mm
Maximum inlet pressure
kA
Outlet pressure
variable from 0.8 to 1.9 bar
Solenoid coil voltage
12 V DC
Solenoid coil power
11 W
Connection at input
M10x1 cable ø6 mm
Connection at output
Hose connection ø12 mm
Power in KW
160

*Colder temperatures can reduce the efficiency of the reducer and the performance of the motor; in the case of higher ambient temperatures, the reducer can also be used on more powerful motors.

Safety instructions and warnings

Safety instructions for KME reducer SILVER S6 up to 160KW incl. 6mm shut-off valve

1. observe the manufacturer's instructions and safety instructions before using the KME reducer SILVER S6 up to 160KW incl. 6mm shut-off valve.

2 Ensure that the product is properly installed and connected to ensure safe use.

3. regularly check the condition of the reducer and the shut-off valve to detect possible damage or signs of wear at an early stage.

4. if problems or irregularities occur, contact the manufacturer or an authorised specialist immediately.

5. use the KME reducer SILVER S6 up to 160KW incl. 6mm shut-off valve only for the intended purpose and within the specified operating parameters.

6 Ensure that the reducer and the shut-off valve are serviced and repaired by qualified personnel.

7. always keep the working area around the reducer clean and free of flammable materials.

8 Observe all applicable safety rules and regulations, especially with regard to the operation of refrigeration systems.

9. switch off the reducer and the shut-off valve during maintenance work or longer periods of standstill and disconnect them from the mains power supply.

10. wear suitable protective equipment, such as gloves and eye protection, when servicing or repairing the reducer and shut-off valve.

11. keep the manufacturer's instructions, safety instructions and other relevant documents for future reference.

Manufacturer contact information

Manufacturer Contact

KME Sp. z o.o.

Aleksandra 24/26

93-418 ?ód?, Poland

kme@kme.eu

Subscribe to our newsletter