- Product description
- Media & Downloads
Charging programmes1
"Gel": Charging programme for gel batteries, characteristic curve IU1oU2oU3
Adapted to sealed, gas-tight gel/dryfit batteries with fixed electrolyte, which generally require a higher charging voltage level and longer U1 holding times in order to achieve short charging times with particularly high capacity storage and to avoid long-term battery "starvation".
2"AGM": Charging programme for AGM/fleece batteries, characteristic curve IU1oU2oU3
Intended for charging sealed, gas-tight AGM (Absorbent Glass Mat) batteries in lead-fleece technology, which require a particularly high U1 level with coordinated holding times for full charging and then a moderate U2 level for charge retention (plate and round cell technology).
4 "UNIVERSAL": Charging programme for lead-acid/wet/AGM batteries, characteristic curve IU1oU2oU3
Universal programme for charging and charge retention of acid batteries in vehicles (mixed mobile/stationary).
With a medium U1 level, still offers short charging times, a good charging factor and good acid mixing for open and closed, low-maintenance, maintenance-free standard, traction, lighting, solar and heavy-duty batteries, as well as AGM batteries with a normal U1 level.
Li "LiFePO4": Charging programme for lithium batteries, characteristic curve IU1oU2oU3
Charging programme tailored to lithium LiFePO4 batteries with their own BMS and prescribed or built-in protective circuitry.
Technical data
Input from vehicle starter battery + IN Start" | |
Vehicle starter battery Nominal voltage | 12 V |
Battery capacity (size), minimum recommended | 80 Ah |
Input voltage range (EURO 6 +), D+ controlled | 10,5 - 16,5 V |
Input overvoltage cut-off (EURO 6 +), max. | 16,5 V |
Power consumption max. | 1085 W |
Current consumption (at lowest input voltage) max. | 0.1 A - 95 A |
Current consumption limited, 3 switch positions "IN Limit" | 77 A, 63 A, 50 A |
Secondary charging branch, charging/charge retention for 12 V starter battery | |
with external mains charging operation, switch position "B" | 0 - 5 A |
Activation control input "D+", from D+, terminal 15, ignition | 8 - 16,5 V |
IN "Start" voltage sensor cables "Vs-" and "Vs+" | yes / yes |
Switching output "TR", signal for bypass relay /max. | 12 V / 1 A |
Charging output on on-board supply battery "+ OUT Bord" | |
Charging/buffer/load current, regulated IU1oU2, lead, LiFePO | 0 A - 70 A |
Reduction with switch position "OUT Limit" | 0 A - 50 A |
Lead-acid, -gel, -AGM battery Nominal voltage | 12 V |
Capacity (battery size), recommended / up to | 100-460 / 620 Ah |
Lead charging programmes stored in the memory | 4 |
Pre-charge current (battery deep discharge < 8V), max. | 35 A |
Safety charging voltage for battery overtemperature | 12,80 V |
LiFePO4 battery nominal voltage | 12 V (12.8 -13.3 V) |
Capacity (battery size), recommended / up to | 100-460 / 620 Ah |
LiFePO4 charging programmes stored in the memory | 4 |
Safety charging voltage for battery overtemperature | 12,80 V |
"T T" Input for battery temperature sensor "Bord" | yes |
OUT "Bord" voltage sensor cables "Vb-" and "Vb+" | yes / yes |
Quiescent current, standby | 16 mA |
Charging timer | 3-fold |
Voltage ripple | < 30 mV rms |
Charging voltage limit "+OUT Bord" (protection of consumers) | 15,00 V |
External overvoltage switch-off "+OUT Bord" (20 sec) | 15,50 V |
Short-circuit/back-discharge/safety protection | yes |
Device installation position | Any |
Temperature range | -20 to 45° |
Speed-controlled, temperature-controlled fan | Yes |
Gradual reduction of charging power in the event of overtemperature | Yes |
Safety shutdown in the event of overheating | Yes |
Dimensions, incl. mounting flanges and terminals (LxWxH) | 235 x 160 x 72 mm |
weight | 1300 g |
Ambient conditions, humidity: max. 95 % room humidity, non-condensing | |
Scope of delivery: Temperature sensor, operating instructions |
Safety instructions and warnings
Safety instructions for Votronic charging converter, B2B charger VCC 1212-70
General safety instructions:
- Read the instructions carefully before commissioning the device.
- Observe the applicable national and regional regulations for electrical installations.
- The device may only be installed and maintained by qualified specialists.
- Ensure that the appliance is properly earthed.
- Do not make any changes or modifications to the device.
- Do not use the appliance in the vicinity of flammable or explosive materials.
Safety and operating instructions:
- Ensure that the input voltage corresponds to the specified values.
- Regularly check the condition of the connection cables and the device for damage.
- Keep the device away from water and moisture.
- Do not expose the device to direct sunlight or heat sources.
- Only use original accessories and spare parts from the manufacturer.
- Disconnect the appliance from the power supply before carrying out maintenance work or repairs.
- Remove the batteries or switch off the appliance if it will not be used for a long period of time.
- Do not carry out any repairs to the appliance yourself. Contact authorised customer service.
- Keep the appliance away from children and pets.
- In the event of malfunctions or damage to the appliance, switch it off immediately and disconnect the mains plug.
Manufacturer Contact information
Manufacturer Contact
VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach
https://www.votronic.de/kontakt/