- Product description
LEDoffSystemswitched off, gas supply switched off.
LEDgreenSystemswitched on; gas supply switched on, operating bottle full
LEDredGassupply switched off; sloping position or excessive acceleration values have led to triggering, e.g. in the event of an accident.
LEDyellowSystemswitched on; gas supply switched on; operating cylinder empty
LED flashes yellowSelf-check for approx. 2 seconds after switching on
LED flashes red1 timeValve not connected to control unit or internal error
LED flashes red2 timesOvervoltage (supply voltage >15V)
Check batteries if necessary
LED flashes3 timesred Undervoltage (supply voltage <10.0V)
Reset time < 45 seconds; check batteries if necessary
Functional behaviour of the changeover switch
- After checking that the display of the automatic change-over switch for both lever positions remains green
turn the arrow either to the right or to the left. The arrow on the lever points to the
operating bottle.
- The display of the automatic switch-over is red (LED on the remote display yellow), which means,
that the operating bottle has been used up. The system then works with the
reserve cylinder.
- If the display of the automatic switchover is red (LED on the remote display is yellow), but the
the operating cylinder has not been completely used up, the changeover process can be stopped by triggering the
hose rupture protection on the high-pressure hose of the operating bottle or by
blockage of the regulator input, e.g. by dirt particles.
To resetthe system, press the switch on the display unit that closes the solenoid valve.
closes. The LED display goes out. After a period of approx. 45 seconds, the system can be restarted by pressing the switch again.
the system can be put back into operation by pressing the switch again.
When taking the system out of operation
close the cylinder valves.
If the system is not to be used for a longer period of time, disconnect the battery - see the operating instructions for the vehicle.