Technical data KME SILVER FZ8 reducer

Evaporator material
Cast aluminium
weight
1.33 kg
Dimensions
119x96 mm
Maximum inlet pressure
kA
Outlet pressure
variable from 0.6 to 1.7 bar
Solenoid coil voltage
12 V DC
Solenoid coil power
11 W
Connection at input
M12x1 cable ø8 mm
Connection at output
Hose connection ø12 mm
Power in KW
180

*Colder temperatures can reduce the efficiency of the reducer and the performance of the motor; in the case of higher ambient temperatures, the reducer can also be used on more powerful motors.

Safety instructions and warnings

Safety instructions for KME reducer SILVER S8 up to 177KW incl. 8mm shut-off valve

Important safety instructions:

  • Installation and maintenance of the reducer may only be carried out by qualified personnel.
  • The vaporiser system may only be operated with the components recommended or approved by the manufacturer.
  • Before installing the vaporiser system, it must be ensured that all components are correctly installed and dimensioned.
  • The national and local regulations and standards must be observed for the installation and commissioning of the vaporiser system.
  • The use of unauthorised or damaged components can lead to serious personal injury or damage to property.
  • Observe the safety regulations when working on the LPG conversion kit.
  • Carry out regular maintenance work in accordance with the manufacturer's instructions.
  • Observe the warnings and safety instructions in the operating instructions.

Operating instructions:

  • The reducer may only be used in intended and suitable applications.
  • The reducer must always be installed in an upright position.
  • The vaporiser system may only be commissioned by qualified personnel.
  • The vaporiser system must be properly vented before it is put into operation.
  • The vaporiser system may only be operated in well-ventilated areas.
  • The operating instructions must be accessible at all times.
  • Do not use the reducer if it is damaged or leaking.
  • The reducer must be protected from frost and overheating.