  • 2 completely independent charging sections in one unit
  • Charging programmes no. 1, 2, 3 and 5 (gel, AGM, acid, start) adjustable to battery type for each charging unit
  • Battery capacity can be set 4 times for each charging section (16 charging programmes in total)
  • Outstanding charging technology
  • Signal output (MA) +86 for engine start inhibition when vehicle is connected to mains supply
  • Automatic battery regeneration during long idle periods (twice a week)
  • Compensation of voltage losses on the charging cables for exact compliance with charging voltages
  • Disconnection of batteries in case of mains failure, overheating, malfunction (safety switch per charging output)
  • Electronics protected against moisture
  • Charging voltages are free of peaks and regulated to exclude overcharging
  • Fully automatic continuous operation for batteries always ready for use
  • Precise battery temperature compensation, temperature sensor included in delivery
  • Intelligent microprocessor control takes into account the simultaneous supply of loads to the battery
  • Inputs for voltage sensor cables, optionally usable with overlong charging cables or with external lossy diode charging current distributors

Optional accessories:

  • Remote indicator S (art. 2078)
  • Remote operating display IP67 (art. 2081)
  • Charger State Monitor IP67 (Art. 2082)
Charging power in [V]/[A]12 / 15 / 15
Rated voltage (AC) in [V]230
Operating voltage range (AC) in [V]190 - 265 (full charging capacity)
Power consumption (AC) in max. [W]480
Sinusoidal power factor correction (CosPhi = 1)yes
Nominal battery voltage (DC) in [V]12
Battery capacity in [Ah]36 - 170 / 36 - 170
Charging current in [A]15 / 15
Auxiliary charging output "S" in [A]-
Charging characteristicIU1oU2
Voltage limitation for all charging types/programmes [V]15
Voltage ripple in [mV] rms< 50
Number of charging outputs2 + S
Device installation positionany
Temperature range [°C]-20 to +45
Degree/class of protectionI / IP 21
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections305 x 90 x 265
Weight in [g]3700
Standards (CE)EN 60335-2-29
Ambient conditions, humidity: max. 95% room humidity, non-condensing
Scope of delivery: Mains cable, 2 temperature sensors, operating instructions