- Product description
- 2 completely separate and independent charging units in one device
- Charging programmes no. 1, 2, 3 and 5 (gel, AGM, acid, start) adjustable to battery type for each charging unit
- Battery capacity can be set 4 times per charging section (16 charging programmes in total)
- Outstanding charging technology
- Signalling output (MA) +86 for engine start inhibit when connected to the vehicle power supply
- Automatic battery regeneration for long downtimes (twice a week)
- Compensation of voltage losses on the charging cables for exact compliance with the charging voltages
- Disconnection of the batteries in the event of mains failure, overheating, incorrect behaviour (safety switch per charging output)
- Electronics protected against moisture
- The charging voltages are free of peaks and regulated to prevent overcharging
- Fully automatic continuous operation for constant operational readiness of the batteries
- Precise battery temperature compensation, temperature sensor included in the scope of delivery
- Intelligent microprocessor control takes into account the simultaneous co-supply of consumers on the battery
- Inputs for voltage sensor cables, optionally usable with extra-long charging cables or with external lossy diode charging current distributors
Optional accessories:
- Remote display S (Art. 2078)
- Remote operating display IP67 (Art. 2081)
- Charger State Monitor IP67 (Art. 2082)
Technical data
Charging power in [V]/[A] | 12 / 15 / 15 |
Nominal voltage (AC) in [V] | 230 |
Operating voltage range (AC) in [V] | 190 - 265 (full charging capacity) |
Power consumption (AC) in max. [W] | 480 |
Sinusoidal power factor correction (CosPhi = 1) | yes |
Nominal battery voltage (DC) in [V] | 12 |
Battery capacity in [Ah] | 36 - 170 / 36 - 170 |
Charging current in [A] | 15 / 15 |
Auxiliary charging output "S" in [A] | - |
Charging characteristic | IU1oU2 |
Voltage limitation for all charging types/programmes [V] | 15 |
Voltage ripple in [mV] rms | < 50 |
Number of charging outputs | 2 + S |
Device installation position | any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | I / IP 21 |
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections | 305 x 90 x 265 |
Weight in [g] | 3700 |
Standards (CE) | EN 60335-2-29 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: Mains cable, 2 temperature sensors, operating instructions |
Safety instructions and warnings
Safety instructions for Votronic Automatic Charger VAC 1215/15 Duo without emergency start function
- Only use the charger in accordance with the information in the operating instructions. - Do not connect the charger if it is damaged. Contact the manufacturer instead. - Do not use the charger in the vicinity of flammable materials or liquids. - Ensure that the charger is sufficiently ventilated during the charging process to prevent overheating. - The charger must not be used in water or other liquids. - Ensure that children do not use the charger unsupervised. - Disconnect the charger from the power source when it is not in use. - Only use the mains adapter and accessories supplied. - Only clean the charger with a soft, dry cloth. Do not use any aggressive cleaning agents. - Observe all other information and instructions from the manufacturer. Please note that the above safety instructions are general and it is important to read and follow the complete information in the operating instructions for the charger.Manufacturer contact information
Manufacturer Contact
VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach
https://www.votronic.de/kontakt/