  • Charging programmes no. 5, 6, 7, 8 and 9 (start, gel, AGM, acid) adjustable to battery type
  • Outstanding charging technology
  • Fully automatic continuous operation for batteries always ready for use
  • Charging voltages are free of peaks and regulated to exclude overcharging
  • Trouble-free operation and co-supply of the devices connected to the vehicle's electrical system
  • 1 main charging output and 1 additional auxiliary charging output "S" for back-up and trickle charging, e.g. of another starter battery of the same voltage (max. 2A)
  • Starter battery is also charged with full charge current if required (short vehicle standing time)
  • Signal output (MA) +86 for engine start inhibition in case of vehicle mains connection
  • Optical and acoustic warning in case of battery and operating faults
  • Precise battery temperature compensation, temperature sensor included in scope of delivery
  • Automatic battery regeneration during long idle periods (twice a week)
  • Compensation of voltage losses on the charging cables for exact compliance with charging voltages
  • Disconnection of batteries in case of mains failure, overheating, malfunction (safety switch for each charging output)
  • Power supply function enables consumers to continue operation and data retention, e.g. when changing batteries
  • Manual charge start in case of deeply discharged battery according to DIN 14679
  • Variable installation position
  • Electronics protected against moisture
  • Intelligent microprocessor control takes into account the simultaneous supply of loads to the battery
  • Mains/charging power can be reduced in the event of low-power or limited mains supply (power-limit function)

Optional accessories:

  • Remote control S (art. 2075)
  • Remote operating display IP67 (art. 2081)
  • Charger State Monitor IP67 (Art. 2082)
Charging power in [V]/[A]24 / 40
Rated voltage (AC) in [V]230
Operating voltage range (AC) in [V]190 - 265 (full charging capacity)
Power consumption (AC) in max. [W]1380
Sinusoidal power factor correction (CosPhi = 1)Yes
Nominal battery voltage (DC) in [V]24
Battery capacity in [Ah]66 - 200 (400 1)
Charging current in [A]40
Auxiliary charging output "S" in [A]2
Charging characteristicIU1oU2
Voltage limitation for all charging types/programmes [V]30
Voltage ripple in [mV] rms< 80
Number of charging outputs1 + S + MA
Device installation positionany
Temperature range [°C]-20 to +45
Degree/class of protectionI / IP 21
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections305 x 90 x 265
Weight in [g]3900
Standards (CE)EN 60335-2-29
Ambient conditions, humidity: max. 95% room humidity, non-condensing
Scope of delivery: Mains cable, 1 temperature sensor, operating instructions

1 for vehicle breaks >24 hours, in accordance with DIN 14679