- Product description
- Charging programmes no. 5, 6, 7, 8 and 9 (start, gel, AGM, acid) adjustable to battery type
- Outstanding charging technology
- Fully automatic continuous operation for constant operational readiness of the batteries
- The charging voltages are free of peaks and regulated in such a way that overcharging is ruled out
- Trouble-free operation and co-supply of the devices connected to the vehicle electrical system
- Built-in charging current distributor with 2 main charging outputs, both with maximum current and power capacity
- Charging current distributor output "2" can optionally be switched to a separate charging programme for the starter battery
- Starter battery is also charged with full charging current if required (short vehicle service life)
- Signal output (MA) +86 for engine start inhibit with vehicle mains connection
- Visual and acoustic warning in the event of battery and operating errors
- Precise battery temperature compensation, temperature sensors included in the scope of delivery
- Automatic battery regeneration during long downtimes (twice a week)
- Compensation of voltage losses on the charging cables for exact compliance with the charging voltages
- Disconnection of the batteries in the event of mains failure, overheating, incorrect behaviour (safety switch per charging output)
- Power supply function enables consumers to continue operation and data retention, e.g. when changing batteries
- Manual charging start when battery is deeply discharged in accordance with DIN 14679
- Variable installation position
- Electronics protected against moisture
- Intelligent microprocessor control takes into account the simultaneous co-supply of consumers on the battery
- Mains/charging power can be reduced if the mains supply is weak or limited (power limit function)
Optional accessories:
- Remote control S (Art. 2075)
- Remote operating display IP67 (Art. 2081)
- Charger State Monitor IP67 (Art. 2082)
Technical data
Charging power in [V]/[A] | 24 / 25 |
Nominal voltage (AC) in [V] | 230 |
Operating voltage range (AC) in [V] | 190 - 265 (full charging capacity) |
Power consumption (AC) in max. [W] | 830 |
Sinusoidal power factor correction (CosPhi = 1) | yes |
Nominal battery voltage (DC) in [V] | 24 |
Battery capacity in [Ah] | 40 - 125 (250 1) |
Charging current in [A] | 25 |
Auxiliary charging output "S" in [A] | - |
Charging characteristic | IU1oU2 |
Voltage limitation for all charging types/programmes [V] | 30 |
Voltage ripple in [mV] rms | < 80 |
Number of charging outputs | 2 + MA |
Device installation position | any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | I / IP 21 |
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections | 305 x 71 x 160 |
Weight in [g] | 2400 |
Standards (CE) | EN 60335-2-29 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: Mains cable, 2 temperature sensors, operating instructions |
1 when vehicles are not in use for >24 hours, in accordance with DIN 14679
Safety instructions and warnings
Safety instructions for Votronic Automatic Charger VAC 2425 F 3A
- Always switch off the power supply before installing or maintaining the device.
- Only use the charger indoors and keep it away from moisture and heat-sensitive materials.
- Ensure that the charger is placed on a stable and level surface.
- Only use the mains adapter supplied and do not connect the device to any other power source.
- Do not overcharge the connected battery and ensure that you have set the correct charging voltage.
- Ensure that the charger does not overheat and is sufficiently ventilated.
- Keep the device away from children and pets.
- Before using the charger, read all the instructions supplied carefully and follow them.
- In the event of a defect, contact the manufacturer or authorised customer service to carry out repairs.
Manufacturer contact information
Manufacturer Contact
VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach
https://www.votronic.de/kontakt/