- Product description
- Charging programmes no. 5, 6, 7, 8 and 9 (start, gel, AGM, acid) adjustable to battery type
- Outstanding charging technology
- Fully automatic continuous operation for constant operational readiness of the batteries
- The charging voltages are free of peaks and regulated in such a way that overcharging is ruled out
- Trouble-free operation and co-supply of the devices connected to the vehicle electrical system
- 1 main charging output and 1 additional auxiliary charging output "S" for backup and trickle charging, e.g. another starter battery of the same voltage (max. 2A)
- Starter battery is also charged with full charging current if required (short vehicle service life)
- Signalling output (MA) +86 for engine start inhibit with vehicle mains connection
- Visual and acoustic warning in the event of battery and operating errors
- Precise battery temperature compensation, temperature sensor included in scope of delivery
- Automatic battery regeneration during long downtimes (twice a week)
- Compensation of voltage losses on the charging cables for exact compliance with the charging voltages
- Disconnection of the batteries in the event of mains failure, overheating, incorrect behaviour (safety switch per charging output)
- Power supply function enables consumers to continue operation and data retention, e.g. when changing batteries
- Manual charging start when battery is deeply discharged in accordance with DIN 14679
- Variable installation position
- Electronics protected against moisture
- Intelligent microprocessor control takes into account the simultaneous co-supply of consumers on the battery
- Mains/charging power can be reduced if the mains supply is weak or limited (power limit function)
Optional accessories:
- Remote control S (Art. 2075)
- Remote operating display IP67 (Art. 2081)
- Charger State Monitor IP67 (Art. 2082)
Technical data
Charging power in [V]/[A] | 12 / 80 |
Nominal voltage (AC) in [V] | 230 |
Operating voltage range (AC) in [V] | 190 - 265 (full charging capacity) |
Power consumption (AC) in max. [W] | 1400 |
Sinusoidal power factor correction (CosPhi = 1) | yes |
Nominal battery voltage (DC) in [V] | 12 |
Battery capacity in [Ah] | 120 - 400 (800 1) |
Charging current in [A] | 80 |
Auxiliary charging output "S" in [A] | 2 |
Charging characteristic | IU1oU2 |
Voltage limitation for all charging types/programmes [V] | 15 |
Voltage ripple in [mV] rms | < 50 |
Number of charging outputs | 1 + S + MA |
Device installation position | any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | I / IP 21 |
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections | 305 x 90 x 265 |
Weight in [g] | 3900 |
Standards (CE) | EN 60335-2-29 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: Mains cable, 1 temperature sensor, operating instructions |
1 when vehicles are not in use for >24 hours, in accordance with DIN 14679
Safety instructions and warnings
Safety instructions for Votronic Automatic Charger VAC 1280 F 2A
- The operating instructions and the manufacturer's safety instructions must be read carefully and observed before installation and commissioning.
- The Votronic Automatic Charger VAC 1280 F 2A may only be installed in dry indoor areas.
- The device must not be set up near heat sources such as heaters or exposed to direct sunlight.
- The appliance must not be installed in areas with high humidity or near water.
- The appliance may only be connected to an easily accessible and earthed socket.
- Only original spare parts or spare parts authorised by the manufacturer may be used.
- The appliance may only be installed and serviced by persons who are familiar with the electrical components and safety instructions.
- The appliance must not be opened or repaired unless this is carried out by qualified personnel.
Manufacturer contact information
Manufacturer
VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach
https://www.votronic.de/kontakt/