- Charging programmes no. 1, 2, 3 and 5 (gel, AGM, acid, start) adjustable to battery type
- The charging voltage is free of peaks and regulated in such a way that overcharging of the batteries is ruled out.
- Fully automatic continuous operation: The charger can be permanently connected to the battery and keeps it fully charged. In the event of a mains failure, the batteries are not discharged (disconnection by safety switch).
- Lead-acid battery regeneration twice a week during long downtimes to prevent harmful acid stratification.
- Parallel and buffer operation: The battery continues to be charged or is kept fully charged during simultaneous consumption. The charger automatically calculates and monitors the adjustment of the charging times.
- Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short circuit, polarity reversal, incorrect behaviour and battery back-discharge through electronic cut-off up to complete disconnection of charger and battery by built-in safety switches.
- Connection for battery temperature sensor (supplied with temperature sensor 825): With lead batteries (acid, gel, AGM), the charging voltage is automatically adjusted to the battery temperature, ensuring better full charging of the weaker battery in cold weather and avoiding unnecessary battery gassing and thus battery stress in summer temperatures.
- Silent Run function: Noise-optimised operation at the touch of a button (night mode).
- Mains adapter function: Enables consumers to be supplied without a battery (e.g. when changing batteries).
- Charging cable compensation: Voltage losses on the charging cables are automatically compensated for.
- Built-in on-board mains filter: Problem-free parallel operation with solar systems, wind and petrol generators, dynamos, etc. on one battery.
- Moisture-protected electronics
- Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support for the battery if consumers are still switched on.
- Built-in charging current distributor with 2 main charging outputs, both with maximum current and power capacity
- For mixed operation with 1 supply battery and 1 starter battery, a separate starter charging programme can be set on the built-in charging current distributor
- Starter battery is also charged with full charging current if required (short vehicle service life)
- Separate auxiliary charging output "S" for support and trickle charging of an additional starter battery or as signalling output +86 for engine start inhibit with vehicle mains connection
- Equalisation function (IUIU charging characteristic can be activated manually for cell equalisation charging)
- Battery capacity adjustable in 4 stages (12 charging programmes in total)
- Inputs for voltage sensor (sense) cables, optionally usable with extra-long charging cables and/or external, lossy diode charging current distributors
- Mains/charging power can be reduced in the event of low-power or limited mains supply, e.g. weakly fused shore power supply, generator operation, etc. (power limit function)
- Disconnection of the batteries in the event of mains failure, overheating, malfunction (safety switch per charging output)
- Variable installation position
Optional accessories:
- Remote control S (Art. 2075)
- Remote operating display IP67 (Art. 2081)
- Charger State Monitor IP67 (Art. 2082)
Technical data
Charging power in [V]/[A] | 24 / 25 |
Nominal voltage (AC) in [V] | 230 |
Operating voltage range (AC) in [V] | 190 - 265 (full charging capacity) |
Power consumption (AC) in max. [W] | 830 |
Sinusoidal power factor correction (CosPhi = 1) | yes |
Nominal battery voltage (DC) in [V] | 24 |
Battery capacity in [Ah] | 46 - 290 |
Charging current in [A] | 25 |
Auxiliary charging output "S" in [A] | 4 |
Charging characteristic | IU1oU2 |
Voltage limitation for all charging types/programmes [V] | 30 |
Voltage ripple in [mV] rms | < 80 |
Number of charging outputs | 2 + S |
Device installation position | any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | I / IP 21 |
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections | 305 x 71 x 160 |
Weight in [g] | 2400 |
Standards (CE) | EN 60335-2-29 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: Mains cable, 2 temperature sensors, operating instructions |
Safety instructions and warnings
Safety instructions for Votronic Automatic Charger VAC 2425 M 3A
- Only use the product in accordance with the manufacturer's instructions. - Ensure that the product is properly installed and connected to avoid potential hazards. - Avoid contact with water or moisture to prevent short circuits or other damage. - Only connect the product to a suitable power source and do not use damaged cables or plugs. - Do not overload the product to avoid damage or overheating. - Ensure that the product does not overheat and is sufficiently ventilated to ensure optimum performance. - Keep the product away from children and pets to prevent injury or damage. - Switch off the product before carrying out maintenance or cleaning. - Read the manufacturer's complete operating instructions to use the product safely and efficiently. - In the event of technical problems, contact the manufacturer or authorised specialists.Operating instructions for Votronic Automatic Charger VAC 2425 M 3A
- Check the charge status and battery voltage regularly to ensure optimum performance. - Observe the recommended charging times and modes for different battery types. - Ensure that the batteries are properly connected and well maintained. - Keep the product clean and dry to ensure optimum performance and a long service life. - Follow all specific manufacturer's instructions for use of the product. - Observe the recommended ambient temperature for operating the product. - Store the product in a safe place to prevent damage or theft. - Observe the applicable safety rules and regulations for the use of the product. - If problems or irregularities occur, switch off the product and contact the manufacturer or authorised specialists.Manufacturer contact information
Manufacturer Contact
VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach
https://www.votronic.de/kontakt/