- Charging programmes no. 1, 2, 3 and 5 (gel, AGM, acid, start) adjustable to battery type
- Outstanding charging technology
- The charging voltages are free of peaks and regulated to prevent overcharging
- 1 main charging output and 1 additional auxiliary charging output "S" for support and trickle charging of a starter battery (max. 2 A)
- Starter battery is also charged with full charging current if required (short vehicle service life)
- Fully automatic continuous operation for constant operational readiness of the batteries
- Precise battery temperature compensation, temperature sensor included in the scope of delivery
- Equalisation function (IUIU charging characteristic can be activated manually for cell equalisation charging)
- Intelligent microprocessor control takes into account the simultaneous co-supply of consumers on the battery
- Automatic battery regeneration during long downtimes (twice a week)
- Equalisation of voltage losses on the charging cables for exact compliance with the charging voltages
- Disconnection of the batteries in the event of mains failure, overheating, incorrect behaviour (safety switch per charging output)
- Silent run function can be set (night setback)
- Mains adapter function enables consumers to continue operation and data retention, e.g. when changing batteries
- Electronics protected against moisture
- Variable installation position
- Battery capacity adjustable in 4 stages (16 charging programmes in total)
- Input for sensor (sense) cables, can be used with extra-long charging cables
- Separate signalling output +86 for engine start inhibit with vehicle mains connection
- Voltage equalisation for external diode charging current distributor selectable (+ 0.63V)
- Mains/charging power can be reduced in the event of low-power or restricted mains supply, e.g. weakly fused shore power supply, generator operation, etc. (power limit function)
Optional accessories:
- Remote control S (Art. 2075)
- Remote operating display IP67 (Art. 2081)
- Charger State Monitor IP67 (Art. 2082)
Technical data
Charging power in [V]/[A] | 12 / 80 |
Nominal voltage (AC) in [V] | 230 |
Operating voltage range (AC) in [V] | 190 - 265 (full charging capacity) |
Power consumption (AC) in max. [W] | 1400 |
Sinusoidal power factor correction (CosPhi = 1) | yes |
Nominal battery voltage (DC) in [V] | 12 |
Battery capacity in [Ah] | 150 - 880 |
Charging current in [A] | 80 |
Auxiliary charging output "S" in [A] | 2 |
Charging characteristic | IU1oU2 |
Voltage limitation for all charging types/programmes [V] | 15 |
Voltage ripple in [mV] rms | < 50 |
Number of charging outputs | 1 + S |
Device installation position | any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | I / IP 21 |
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections | 305 x 90 x 265 |
Weight in [g] | 3.900 |
Standards (CE) | EN 60335-2-29 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: Mains cable, 1 temperature sensor, operating instructions |
Safety instructions and warnings
Safety instructions for Votronic Automatic Charger VAC 1280 M 2A
- The charger may only be installed and maintained by authorised specialist personnel.
- Ensure that the device is not installed near water or moisture.
- Ensure that the power supply is switched off before installing or servicing the device.
- Only connect the charger to the recommended battery types.
- Only use the cables and plugs supplied to connect the device.
- Ensure that the cables and plugs are free from damage before connecting the device.
- Avoid placing the charger near flammable materials.
- Ensure that the device does not overheat and is sufficiently ventilated.
- Do not overcharge the batteries and ensure that they are not deeply discharged.
- Read the manufacturer's instructions carefully before installing and using the device.
Manufacturer contact information
Manufacturer Contact
VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach
https://www.votronic.de/kontakt/