- Product description
- Media & Downloads
- Charging programmes no. 1, 2, 3 and 5 (gel, AGM, acid, start) adjustable to battery type
- Outstanding charging technology
- The charging voltages are free of peaks and regulated to exclude overcharging
- 1 main charge output and 1 additional secondary charge output "S" for support and maintenance charging of a starter battery (max. 2 A)
- Starter battery is also charged with full charging current if required (short vehicle standing time)
- Fully automatic continuous operation for constant battery readiness for use
- Precise battery temperature compensation, temperature sensor included in delivery
- Equalisation function (IUIU charging characteristic can be activated manually for cell equalisation charging)
- Intelligent microprocessor control takes into account the simultaneous supply of consumers to the battery
- Automatic battery regeneration during long idle periods (twice a week)
- Compensation of voltage losses on the charging cables for exact compliance with charging voltages
- Disconnection of batteries in case of mains failure, overheating, malfunction (safety switch for each charging output)
- Silent-run function adjustable (night setback)
- Power supply function enables consumers to continue operation and data retention, e.g. when changing batteries
- Electronics protected against moisture
- Variable installation position
- Battery capacity can be set 4 times (16 charging programmes in total)
- Input for sensor (sense) lines, can be used with overlong charging lines
- Separate signal output +86 for engine start inhibit when vehicle is connected to mains supply
- Voltage compensation for external diode charging current distributor selectable (+ 0.63V)
- Mains/charging power can be reduced in case of low-power or limited mains supply, e.g. weakly fused shore power supply, generator operation, etc. (power limit function)
Optional accessories:
- Remote control S (art. 2075)
- Remote operating display IP67 (item 2081)
- Charger State Monitor IP67 (Art. 2082)
Charging power in [V]/[A] | 12 / 60 |
Rated voltage (AC) in [V] | 110 - 230 |
Operating voltage range (AC) in [V] | 115 - 265 (full charging capacity) |
Power consumption (AC) in max. [W] | 1020 |
Sinusoidal power factor correction (CosPhi = 1) | Yes |
Nominal battery voltage (DC) in [V] | 12 |
Battery capacity in [Ah] | 120 - 660 |
Charging current in [A] | 60 |
Auxiliary charging output "S" in [A] | 2 |
Charging characteristic | IU1oU2 |
Voltage limitation for all charging types/programmes [V] | 15 |
Voltage ripple in [mV] rms | < 50 |
Number of charging outputs | 2 + S |
Device installation position | any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | I / IP 21 |
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections | 305 x 90 x 265 |
Weight in [g] | 3.900 |
Standards (CE) | EN 60335-2-29 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: Mains cable, 2 temperature sensors, operating instructions |