- Product description
- Charging programmes no. 5, 6, 7, 8, 9 and 10 can be set for all battery types
- Automatic, fast and gentle full charge and charge retention of the vehicle battery in accordance with DIN 14679
- Trouble-free operation and co-supply of devices connected to the vehicle electrical system (e.g. charging trays)
- Charging plug is automatically disconnected if the battery is missing (to prevent short circuits and plug corrosion)
- Visual and acoustic warning in the event of battery and operating errors
- Outstanding charging technology
- Fully automatic continuous operation for constant operational readiness of the batteries
- Compensation of voltage losses on the charging cables for exact compliance with the charging voltages
- Variable installation position
- Electronics protected against moisture
- The charging voltages are free of peaks and regulated to prevent overcharging
- Automatic battery regeneration during long downtimes (twice a week)
- Provided for a further cable extension optionally with:
- Automatic cable retractor 5m (max. 16A charging current) Art. 2315 or
- Spiral charging cable 5m complete with charging plug Art. 2319 or
- Spiral charging cable 5m Art. 2318 with C-plug Art. 2323 or charging plug Art. 2331
Optional accessories:
- Remote control S (Art. 2075)
- Remote operating display IP67 (Art. 2081)
- Charger State Monitor IP67 (Art. 2082)
- Automatic cable reel with 5m cable (Art. 2315)
- Spiral charging cable 5m complete with charging plug (Art. 2319)
- Spiral charging cable (Art. 2318) with C-plug (Art. 2323) or charging plug (Art. 2331)
- Connection box (Art. 2310)
Technical data
Charging power in [V]/[A] | 24 / 16 |
Nominal voltage (AC) in [V] | 230 |
Operating voltage range (AC) in [V] | 190 - 265 (full charging capacity) |
Power consumption (AC) in max. [W] | 530 |
Sinusoidal power factor correction (CosPhi = 1) | Yes |
Nominal battery voltage (DC) in [V] | 24 |
Battery capacity in [Ah] | 70 - 160 |
Charging current in [A] | 16 |
Auxiliary charging output "S" in [A] | - |
Charging characteristic | IU1oU2 |
Voltage limitation for all charging types/programmes [V] | 30 |
Voltage ripple in [mV] rms | < 50 |
Number of charging outputs | 1 |
Device installation position | any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | I / IP 21 |
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections | 210 x 71 x 160 |
Weight in [g] | 1400 |
Standards (CE) | EN 60335-2-29 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: Mains cable, oil flex cable ®, operating instructions |
Safety instructions and warnings
Safety instructions for Votronic Automatic Charger VAC 2416 Station with oil flex cable 4m:
1. read the manufacturer's instructions carefully before using the product.
2. ensure that the product is only used in accordance with the manufacturer's instructions and the applicable safety standards.
3. use the supplied oil flex cable 4m only for its intended purpose and check it regularly for damage.
4. ensure that the product is properly connected to a suitable power source.
5. avoid contact of the product with water or other liquids.
6. keep the product away from flammable materials.
7. check the charge status of the product regularly and contact the manufacturer if there are any irregularities.
8. observe the manufacturer's safety and operating instructions for the specific model Votronic Automatic Charger VAC 2416 Station with oil flex cable 4m.
9. in the event of technical problems or uncertainties, contact the manufacturer or authorised customer service.
10. keep the product out of the reach of children and pets.
Manufacturer contact information
Manufacturer Contact
VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach
https://www.votronic.de/kontakt/