- Product description
- Charging programmes no. 1, 2, 3 and 5 (gel, AGM, acid, start) as well as 4x Lithium-LiFePO4 adjustable to battery type
- The charging voltage is free of peaks and regulated in such a way that the batteries cannot be overcharged.
- Fully automatic continuous operation: The charger can be permanently connected to the battery and keeps it fully charged. In the event of a mains failure, the batteries are not discharged (disconnection by safety switch).
- Lithium LiFePO4 maintenance, auto wake-up, maintenance phase: Regular automatic activation of battery cell balancing every 10 days to ensure that the battery is always fully charged.
- Lead battery regeneration twice a week during long downtimes to prevent harmful acid stratification.
- Parallel and buffer operation: The battery continues to be charged or kept fully charged during simultaneous consumption. The charger automatically calculates and monitors the adjustment of the charging times.
- Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short circuit, polarity reversal, incorrect behaviour and battery back-discharge through electronic cut-off up to complete disconnection of charger and battery by built-in safety switches.
- Connection for battery temperature sensor (supplied with temperature sensor 825): With lead batteries (acid, gel, AGM), the charging voltage is automatically adjusted to the battery temperature, ensuring better full charging of the weaker battery in cold weather and avoiding unnecessary battery gassing and thus battery stress in summer temperatures.
With LiFePO4 batteries, the battery temperature sensor is required for the device to function: It serves to protect the battery at high and especially at low temperatures below 0°C. - Silent Run function: Noise-optimised operation at the touch of a button (night mode).
- Power supply unit function: Enables consumers to be supplied without a battery (e.g. when changing batteries).
- Charging cable compensation: Voltage losses on the charging cables are automatically compensated for.
- Built-in on-board mains filter: Problem-free parallel operation with solar systems, wind and petrol generators, dynamos, etc. on one battery.
- Moisture-protected electronics
- Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support for the battery if consumers are still switched on.
- Built-in charging current distributor with 2 main charging outputs, both with maximum current and power capacity
- For mixed operation with 1 supply battery and 1 starter battery, a separate starter charging programme can be set on the built-in charging current distributor
- Starter battery is also charged with full charging current if required (short vehicle service life)
- Separate auxiliary charging output "S" for support and trickle charging of an additional starter battery or as signalling output +86 for engine start inhibit with vehicle mains connection
- Equalisation function (IUIU charging characteristic can be activated manually for cell equalisation charging)
- Battery capacity adjustable in 4 stages (12 charging programmes in total)
- Inputs for voltage sensor (sense) cables, optionally usable with extra-long charging cables and/or external, lossy diode charging current distributors
- Mains/charging power can be reduced in the event of low-power or limited mains supply, e.g. weakly fused shore power supply, generator operation, etc. (power limit function)
- Disconnection of the batteries in the event of mains failure, overheating, malfunction (safety switch per charging output)
- Variable installation position
Optional accessories:
- Remote control S (Art. 2075)
- Remote operating display IP67 (Art. 2081)
- Charger State Monitor IP67 (Art. 2082)
Technical data
Mains voltage (mains frequency 45 - 65 Hz) | 110 V - 230 V |
Mains function voltage range, all types | 85 V - 270 V, briefly 305 V (5 sec.) |
Mains voltage range for full charging power | 190 V - 270 V |
Mains power consumption max. | 1020 W |
Mains current consumption (AC) max: | 5,2 A |
Active sinusoidal power factor correction (CosPhi < = 1) | yes |
Charging current approx. at 110 V mains voltage | 34 A |
"AC Power Limit" switch, limitation of mains current consumption / power: | |
"Max" position (maximum charging power): | 5.2 A / 1020 W |
Med" position (reduced mains and charging power): | 2.4 A / 500 W |
Low" position (reduced mains and charging power): | 1.9 A / 390 W |
Battery charging outputs "A" + "B": | |
Nominal battery voltage lead/ LiFePO4 battery | 12 V / 12 V-13.3 V |
Adjustable battery capacity (A or A+B total) | 110Ah - 660Ah |
Charging current I-phase (A, B or A+B) max | 60 A |
Charging/buffer/load current, regulated U1, U2, U3 phase | 0 A - 60 A |
Automatic charging current distributor for batteries A / B: | yes |
Minimum battery voltage for start of charging | 0 V |
Pre-charge current, deep discharged batteries 0 V - 8 V | 30 A |
Reverse current from battery (mains failure) | < 0.2 mA |
Reset voltage (30 sec), depending on battery type | 12.75 V / 13.25 V |
Charging voltage limit (protection of connected loads) | 15,0 V |
External overvoltage cut-off (20 sec) | 15,5 V |
Voltage ripple | < 40 mV rms |
Charging timer | 4-fold |
Reverse polarity/short circuit/back discharge/safety protection | yes |
Safety timer per charging phase I-/U1-/U2- | yes |
Sensor lines "Sense" inputs, for "-" battery and "+A", "+B" | yes |
Lead-acid battery regeneration for long downtimes, 2x 1 h per week | yes |
LiFePO4-Auto Wake Up for long service life, 10 daily 0.5 h | yes |
or LiFePO4-Lithium rest maintenance (seasonal operation) | yes |
Manual lead-acid equalisation charge, equalisation, "Cap." charge current switch | 4,4/5,8/8,4/13,9A |
Equalisation, charging voltage/charging time limitation max. | 16.0 V / 1.5 h |
Main charging output battery "A" (master): | |
Selectable charging programmes lead-gel/AGM/acid, LiFePO4 | 8 |
Charging/buffer/load current, regulated IU1oU2oU3 phase | 0 A - 60 A |
Input for battery temperature sensor | Yes |
Power supply operation (e.g. continued supply when changing batteries) | yes |
2nd charging output battery "B" (built-in charging current distributor, switchable): | |
Charging programmes optionally the same as battery "A" Master | yes |
or charging programme for vehicle (lead) starter battery | Yes |
Charging/buffer/load current, regulated IU1oU2oU3 phase | 0 A - 60 A |
Input for battery temperature sensor "B" | yes |
Power supply operation (e.g. continued supply when changing the battery) | yes |
3. next to charging output "C" (mains signalling output): | |
Nominal battery voltage (lead) | 12 V |
Charging current or load capacity as signalling output | 0 A - 2 A |
Overcharge / reverse polarity / short circuit / reverse discharge / safety protection | Yes |
Connection for Automatic Charger remote control | yes |
Device installation position | any |
Temperature range | -20/+45°C |
Speed-controlled, temperature-controlled fan | Yes |
Gradual reduction of charging power in the event of overtemperature | Yes |
Safety shutdown in the event of overheating | yes |
Fan noise reduction, night operation (silent run) | yes |
Protection class / protection type: | I / IP21 |
Dimensions, incl. mounting flanges (W/H/D) | 160 x 72 x 305 mm |
Weight | 2500 g |
Ambient conditions, humidity | max. 95 % RH, non-condensing |
Safety regulations | EN 60335-2-29 |
Scope of delivery: Mains cable, 2 temperature sensors, operating instructions |
Safety instructions and warnings
Safety instructions for Votronic Automatic Charger VAC 1260 M 3A
- Always disconnect the power supply before installing or maintaining the charger.
- Only use the charger in dry environments.
- Never use the charger near water or damp areas.
- Do not use the charger near flammable materials.
- Do not open the charger or attempt to repair it unless you are qualified to do so.
- Keep the charger away from children and pets.
- Only use the charger in accordance with the manufacturer's instructions.
- Do not overload the charger and do not use damaged cables or plugs.
- If the charger overheats or emits unusual noises or odours, disconnect it from the power supply immediately and contact the manufacturer.
- Observe all other safety instructions in the manufacturer's manual.
Manufacturer contact information
Manufacturer Contact
VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach
https://www.votronic.de/kontakt/