- Charging programmes no. 1, 2 and 4 (gel, AGM, acid) adjustable to battery type
- The charging voltage is free of peaks and regulated in such a way that overcharging of the batteries is ruled out.
- Fully automatic continuous operation: The charger can be permanently connected to the battery and keeps it fully charged. In the event of a mains failure, the batteries are not discharged (disconnection by safety switch).
- Lead-acid battery regeneration twice a week during long downtimes to prevent harmful acid stratification.
- Parallel and buffer operation: The battery continues to be charged or is kept full during simultaneous consumption. The charger automatically calculates and monitors the adjustment of the charging times.
- Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short circuit, polarity reversal, incorrect behaviour and battery back-discharge through electronic cut-off up to complete disconnection of charger and battery through built-in safety switches.
- Connection for battery temperature sensor (accessory temperature sensor 825, art. no. 2001): With lead batteries (acid, gel, AGM), the charging voltage is automatically adjusted to the battery temperature, ensuring a better full charge of the weaker battery in cold weather and avoiding unnecessary battery gassing and thus battery stress in summer temperatures.
- Silent Run function: Noise-optimised operation at the touch of a button (night operation).
- Power supply function: Enables consumers to be supplied without a battery (e.g. battery replacement).
- Charging cable compensation: Voltage losses on the charging cables are automatically compensated for.
- Built-in on-board power supply filter: Problem-free parallel operation with solar systems, wind and petrol generators, dynamos etc. on one battery.
- Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, gel, AGM) battery up to 8 V, then powerful support for the battery if consumers are still switched on.
- Disconnection of the batteries in the event of mains failure, overheating, malfunction (safety switch per charging output)
- Separate auxiliary charging output "S" for supporting and trickle charging the vehicle starter battery
Optional accessories:
- Remote control S (Art. 2075)
- Remote operating display IP67 (Art. 2081)
- Charger State Monitor IP67 (Art. 2082)
- Temperature sensor 825 (Art. 2001)
Technical data
Charging power in [V]/[A] | 24 / 16 |
Nominal voltage (AC) in [V] | 230 |
Operating voltage range (AC) in [V] | 190 - 265 (full charging capacity) |
Power consumption (AC) in max. [W] | 520 |
Sinusoidal power factor correction (CosPhi = 1) | Yes |
Nominal battery voltage (DC) in [V] | 24 |
Battery capacity in [Ah] | 40 - 200 |
Charging current in [A] | 16 |
Auxiliary charging output "S" in [A] | 2 |
Charging characteristic | IU1oU2 |
Voltage limitation for all charging types/programmes [V] | 30 |
Voltage ripple in [mV] rms | < 60 |
Number of charging outputs | 1 + S |
Device installation position | any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | I / IP 21 |
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flange/feet, without connections | 228 x 139 x 74 mm |
Weight in [g] | 1.400 |
Standards (CE) | EN 60335-2-29 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: mains cable, operating instructions |
Safety instructions and warnings
Safety instructions for Votronic Automatic Charger Pb 2416 SMT 2B:
1. before connecting the device to the power supply, please ensure that all connections and cables are connected correctly.
2. the device is designed for indoor use and should be protected from moisture and extreme heat.
3. please do not attempt to open or repair the appliance as this may result in serious injury or damage.
4. the appliance shall not be used by children or persons with reduced physical, sensory or mental capabilities unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
5 Do not place any objects on the appliance and ensure that there is sufficient air circulation around the appliance.
6. the appliance may only be connected to a suitable power source and must not be overloaded.
7. when using the appliance near water or in humid environments, appropriate safety precautions must be taken to avoid accidental immersion of the appliance in water.
8. please switch off the appliance and disconnect it from the mains when it is not in use or during long periods of absence.
Manufacturer contact information
Manufacturer Contact
VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach
https://www.votronic.de/kontakt/