  • Product description
  • Charging programmes no. 1, 2, 3 and 5 (gel, AGM, acid, start) adjustable to battery type
  • The charging voltage is free of peaks and regulated in such a way that overcharging of the batteries is ruled out.
  • Fully automatic continuous operation: The charger can be permanently connected to the battery and keeps it fully charged. In the event of a mains failure, the batteries are not discharged (disconnection by safety switch).
  • Lead-acid battery regeneration twice a week during long downtimes to prevent harmful acid stratification.
  • Parallel and buffer operation: The battery continues to be charged or is kept fully charged during simultaneous consumption. The charger automatically calculates and monitors the adjustment of the charging times.
  • Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short circuit, polarity reversal, incorrect behaviour and battery back-discharge through electronic cut-off up to complete disconnection of charger and battery by built-in safety switches.
  • Connection for battery temperature sensor (supplied with temperature sensor 825): With lead batteries (acid, gel, AGM), the charging voltage is automatically adjusted to the battery temperature, ensuring a better full charge of the weaker battery in cold weather and avoiding unnecessary battery gassing and thus battery stress in summer temperatures.
  • Silent Run function: Noise-optimised operation at the touch of a button (night mode).
  • Mains adapter function: Enables consumers to be supplied without a battery (e.g. when changing batteries).
  • Charging cable compensation: Voltage losses on the charging cables are automatically compensated for.
  • Built-in on-board mains filter: Problem-free parallel operation with solar systems, wind and petrol generators, dynamos, etc. on one battery.
  • Moisture-protected electronics
  • Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support for the battery if consumers are still switched on.
  • Built-in charging current distributor with 2 main charging outputs, both with maximum current and power capacity
  • For mixed operation with 1 supply battery and 1 starter battery, a separate starter charging programme can be set on the built-in charging current distributor
  • Starter battery is also charged with full charging current if required (short vehicle service life)
  • Separate auxiliary charging output "S" for support and trickle charging of an additional starter battery or as signalling output +86 for engine start inhibit with vehicle mains connection
  • Equalisation function (IUIU charging characteristic can be activated manually for cell equalisation charging)
  • Disconnection of the batteries in the event of mains failure, overheating, malfunction (safety switch per charging output)
  • Variable installation position

Optional accessories:

  • Remote control S (Art. 2075)
  • Remote operating display IP67 (Art. 2081)
  • Charger State Monitor IP67 (Art. 2082)

Technical data

Charging power in [V]/[A]24 / 16
Nominal voltage (AC) in [V]230
Operating voltage range (AC) in [V]190 - 265 (full charging capacity)
Power consumption (AC) in max. [W]520
Sinusoidal power factor correction (CosPhi = 1)yes
Nominal battery voltage (DC) in [V]24
Battery capacity in [Ah]40 - 200
Charging current in [A]16
Auxiliary charging output "S" in [A]2
Charging characteristicIU1oU2
Voltage limitation for all charging types/programmes [V]30
Voltage ripple in [mV] rms< 50
Number of charging outputs2 + S
Device installation positionany
Temperature range [°C]-20 to +45
Degree/class of protectionI / IP 21
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections210 x 71 x 160
Weight in [g]1450
Standards (CE)EN 60335-2-29
Ambient conditions, humidity: max. 95% room humidity, non-condensing
Scope of delivery: Mains cable, 1 temperature sensor, operating instructions

Safety instructions and warnings

Safety instructions for Votronic Automatic Charger VAC 2416 M 3A:

1. observe the manufacturer's instructions and safety instructions before commissioning the device.

2. ensure that the device is properly connected to a suitable power source

3. use the charger only in accordance with the stated specifications

4. ensure that no liquids get into the device.

5. avoid using the charger near flammable materials.

6. do not touch the charger with wet hands.

7. do not leave the charger unattended during the charging process.

8. switch off the charger before cleaning it or carrying out maintenance work.

9. keep the charger away from children.

10. if you suspect a defect or malfunction of the device, contact the manufacturer or authorised customer service.

Manufacturer contact information

Manufacturer

VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach

https://www.votronic.de/kontakt/

Subscribe to our newsletter
Our newsletter is free of charge and can be canceled at any time here or in your customer account.