- Product description
- Charging programmes no. 1, 2, 3 and 5 (gel, AGM, acid, start) as well as 4x Lithium-LiFePO4 adjustable to battery type
- The charging voltage is free of peaks and regulated in such a way that the batteries cannot be overcharged.
- Fully automatic continuous operation: The charger can be permanently connected to the battery and keeps it fully charged. In the event of a mains failure, the batteries are not discharged (disconnection by safety switch).
- Lithium LiFePO4 maintenance, auto wake-up, maintenance phase: Regular automatic activation of battery cell balancing every 10 days to ensure that the battery is always fully charged.
- Lead battery regeneration twice a week during long downtimes to prevent harmful acid stratification.
- Parallel and buffer operation: The battery continues to be charged or kept fully charged during simultaneous consumption. The charger automatically calculates and monitors the adjustment of the charging times.
- Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short circuit, polarity reversal, incorrect behaviour and battery back-discharge through electronic cut-off up to complete disconnection of charger and battery by built-in safety switches.
- Connection for battery temperature sensor (supplied with temperature sensor 825): With lead batteries (acid, gel, AGM), the charging voltage is automatically adjusted to the battery temperature, ensuring better full charging of the weaker battery in cold weather and avoiding unnecessary battery gassing and thus battery stress in summer temperatures.
With LiFePO4 batteries, the battery temperature sensor is required for the device to function: It serves to protect the battery at high and especially at low temperatures below 0°C. - Silent Run function: Noise-optimised operation at the touch of a button (night mode).
- Power supply unit function: Enables consumers to be supplied without a battery (e.g. when changing batteries).
- Charging cable compensation: Voltage losses on the charging cables are automatically compensated for.
- Built-in on-board mains filter: Problem-free parallel operation with solar systems, wind and petrol generators, dynamos, etc. on one battery.
- Moisture-protected electronics
- Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support for the battery if consumers are still switched on.
- Built-in charging current distributor with 2 main charging outputs, both with maximum current and power capacity
- For mixed operation with 1 supply battery and 1 starter battery, a separate starter charging programme can be set on the built-in charging current distributor
- Starter battery is also charged with full charging current if required (short vehicle service life)
- Separate auxiliary charging output "S" for support and trickle charging of an additional starter battery or as signalling output +86 for engine start inhibit with vehicle mains connection
- Equalisation function (IUIU charging characteristic can be activated manually for cell equalisation charging)
- Disconnection of the batteries in the event of mains failure, overheating, malfunction (safety switch per charging output)
- Variable installation position
Optional accessories:
- Remote control S (Art. 2075)
- Remote operating display IP67 (Art. 2081)
- Charger State Monitor IP67 (Art. 2082)
Technical data
Charging power in [V]/[A] | 24 / 16 |
Nominal voltage (AC) in [V] | 230 |
Operating voltage range (AC) in [V] | 190 - 265 (full charging capacity) |
Power consumption (AC) in max. [W] | 520 |
Sinusoidal power factor correction (CosPhi = 1) | Yes |
Nominal battery voltage (DC) in [V] | 24 |
Battery capacity in [Ah] | 30 - 80 (160 1) |
Charging current in [A] | 16 |
Auxiliary charging output "S" in [A] | - |
Charging characteristic | IU1oU2 |
Voltage limitation for all charging types/programmes [V] | 30 |
Voltage ripple in [mV] rms | < 50 |
Number of charging outputs | 2 + MA |
Device installation position | any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | I / IP 21 |
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections | 210 x 71 x 160 |
Weight in [g] | 1450 |
Standards (CE) | EN 60335-2-29 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: Mains cable, 1 temperature sensor, operating instructions |
1 when vehicles are not in use for >24 hours, in accordance with DIN 14679
Safety instructions and warnings
Safety instructions for Votronic Automatic Charger VAC 2416 F 3A
- The Votronic Automatic Charger VAC 2416 F 3A may only be used for the purposes specified in the data sheet.
- The device may only be connected to a suitable power supply.
- The device must be protected from moisture, wetness and heat.
- The device must not be opened. No modifications may be made to the device.
- Only accessories from Votronic may be used.
- The appliance must be disconnected from the mains before any cleaning or maintenance work.
- Only qualified specialists may carry out work on the device.
- Ensure that the appliance is not damaged.
- Cables must not be damaged or left lying around loose.
- If problems or faults occur, disconnect the appliance from the mains immediately.
Manufacturer Contact information
Manufacturer
VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach
https://www.votronic.de/kontakt/