Votronic Automatic Charger VAC 1220 M 3A
Votronic Automatic Charger VAC 1220 M 3A

Votronic Automatic Charger VAC 1220 M 3A

Article no.: 116088A
Manufacturer: Votronic

Offer is exclusively for commercial customers. Prices are only visible after login.

  • Product description
  • Charging programmes no. 1, 2, 3 and 5 (gel, AGM, acid, start) as well as 4x Lithium-LiFePO4 adjustable to battery type
  • The charging voltage is free of peaks and regulated in such a way that the batteries cannot be overcharged.
  • Fully automatic continuous operation: The charger can be permanently connected to the battery and keeps it fully charged. In the event of a mains failure, the batteries are not discharged (disconnection by safety switch).
  • Lithium LiFePO4 maintenance, auto wake-up, maintenance phase: Regular automatic activation of battery cell balancing every 10 days to ensure that the battery is always fully charged.
  • Lead battery regeneration twice a week during long downtimes to prevent harmful acid stratification.
  • Parallel and buffer operation: The battery continues to be charged or kept fully charged during simultaneous consumption. The charger automatically calculates and monitors the adjustment of the charging times.
  • Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short circuit, polarity reversal, incorrect behaviour and battery back-discharge through electronic cut-off up to complete disconnection of charger and battery by built-in safety switches.
  • Connection for battery temperature sensor (supplied with temperature sensor 825): With lead batteries (acid, gel, AGM), the charging voltage is automatically adjusted to the battery temperature, ensuring better full charging of the weaker battery in cold weather and avoiding unnecessary battery gassing and thus battery stress in summer temperatures.
    With LiFePO4 batteries, the battery temperature sensor is required for the device to function: It serves to protect the battery at high and especially at low temperatures below 0°C.
  • Silent Run function: Noise-optimised operation at the touch of a button (night mode).
  • Power supply unit function: Enables consumers to be supplied without a battery (e.g. when changing batteries).
  • Charging cable compensation: Voltage losses on the charging cables are automatically compensated for.
  • Built-in on-board mains filter: Problem-free parallel operation with solar systems, wind and petrol generators, dynamos, etc. on one battery.
  • Moisture-protected electronics
  • Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support for the battery if consumers are still switched on.
  • Built-in charging current distributor with 2 main charging outputs, both with maximum current and power capacity
  • For mixed operation with 1 supply battery and 1 starter battery, a separate starter charging programme can be set on the built-in charging current distributor
  • Starter battery is also charged with full charging current if required (short vehicle service life)
  • Separate auxiliary charging output "S" for support and trickle charging of an additional starter battery or as signalling output +86 for engine start inhibit with vehicle mains connection
  • Equalisation function (IUIU charging characteristic can be activated manually for cell equalisation charging)
  • Disconnection of the batteries in the event of mains failure, overheating, malfunction (safety switch per charging output)
  • Variable installation position

Optional accessories:

  • Remote control S (Art. 2075)
  • Remote operating display IP67 (Art. 2081)
  • Charger State Monitor IP67 (Art. 2082)

Technical data

Mains voltage (mains frequency 45 - 65 Hz)110 V - 230 V
Mains function voltage range, all types85 V - 270 V, briefly 305 V (5 sec.)
Mains voltage range for full charging power180 V - 270 V
Mains power consumption max.330 W
Current consumption (AC) max.2,7 A
Appliance switch Stand-by1,2 W
Active sinusoidal power factor correction (CosPhi < = 1)yes
Charging current approx. at 110V mains voltage18 A
Charging outputs battery I + II
Nominal battery voltage lead/ LiFePO4 battery12V / 12V-13.3V
Battery capacity I or I+II (recommended)80 Ah - 145 Ah
Battery capacity I or I+II (depending on application)50 Ah - 230 Ah
Charging current Main charge total, I-phase, 8 V to U1; 0-15.5 h20 A
Charging/buffer/load current, regulated U1-U2-U3 phase0 A - 20 A
Automatic charging current distributor for Batt. I / Batt. IIYes
Minimum battery voltage for start of charging0 V
Pre-charge current, deep discharged batteries 0 V - 8 V10,0 A
Reverse current from battery (mains failure)< 0.5 mA
Reset voltage (30 sec), depending on battery type12.75 V / 13.25 V
Charging voltage limit (protection of connected loads)15,0 V
External overvoltage cut-off (20 sec)15,5 V
Voltage ripple< 30 mV rms
Charging timer4-fold
Reverse polarity/short circuit/back discharge/safety protectionyes
Safety timer per charging phase I/U1/U2yes
Lead-acid battery regeneration for long service life, 2x 1 h per weekyes
LiFePO4 Auto-Wake Up during long downtime, 10 days 0.5 hyes
or LiFePO4 Lithium rest maintenance (seasonal operation)yes
Manual lead-acid equalisation charge, equalisation, charging current3,0 A
Equalisation, charging voltage/charging time limitation max.16.0 V / 1.5 h
Main charging output battery I (master)
Selectable charging programmes lead-gel/AGM/acid, LiFePO48
Charge/buffer/load current, regulated IU1oU2oU3 phase0 A - 20 A
Input for battery temperature sensorYes
Power supply operation (e.g. continued supply when changing batteries)yes
2nd charging output battery II (built-in charging current distributor, switchable)
8 charging programmes optionally the same as battery Iyes
or charging programme for vehicle (lead) starter batteryYes
Charging/buffer/load current, regulated IU1oU2oU3 phase0 A - 20 A
3. in addition to charging output III (signalling output mains)
Nominal battery voltage (lead)12 V
Charging current or load capacity as signalling output0 A - 2 A
Reverse polarity/short circuit/back discharge/safety protectionYes
Connection for Automatic Charger remote controlyes
Device installation positionany
Temperature range-20/+45 °C
Speed-controlled, temperature-controlled fanYes
Gradual reduction of charging power in the event of overtemperatureYes
Safety shutdown in the event of overheatingyes
Fan noise reduction, night operation (silent run)yes
Protection class/protection typeI / IP21
Dimensions - Dimensions incl. mounting flanges, without connections205 x 160 x 72 mm
weight1280 g
Ambient conditions, humiditymax. 95 % RH, non-condensing
Safety regulationsEN 60335-2-29
Scope of delivery Mains cable, 1 temperature sensor, operating instructions

Safety instructions and warnings

Safety instructions for Votronic Automatic Charger VAC 1220 M 3A

1 The charger may only be installed and maintained by qualified personnel.

2. ensure that the charger is not installed near flammable materials or liquids.

3. do not use the charger in damp environments or near water.

4. do not connect the charger if the battery terminals are damaged or corroded.

5. only use the power adapter supplied to operate the Charger.

6 Only use the charger in accordance with the manufacturer's instructions.

7. the charger should be kept away from children and pets.

8. if the charger is damaged or does not function properly, contact the manufacturer immediately.

Manufacturer contact information

Manufacturer Contact

VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach

https://www.votronic.de/kontakt/

Subscribe to our newsletter
Our newsletter is free of charge and can be canceled at any time here or in your customer account.