- Product description
- Technical details
These tank sensors have been specially designed for level measurement of water and water-containing media (fresh water, waste water, grey and service water, faecal) in metal or plastic tanks and are therefore universally applicable. The measuring electrode can be easily shortened to the height of the tank and the exact "full" adjustment is carried out by means of an adjuster on the device. In the case of the tank electrodes 12-24 K / 15-50 K and 20 K-WC, "dry" adjustment is also possible with the aid of a scale.
- Simple adjustment to the specified tank level
- Linear, stepless signal of the fill level
- Suitable for 12V and 24V continuous operation
Tank electrode 30-110 K-FL:
- Flexible cable probe, easy to shorten to tank height
- Installation diameter 38 mm (or PG 29 thread)
- Flange diameter 46.5 mm
- Connection cable 75 cm long
Accessories
Single switch 2xUM with flat plug connection (e.g. switch panel 16A S - art. 1289 or switch panel 2x 16A S - art. 1291), suitable for optionally operating a second tank on the same display (e.g. indoor/outdoor tank, summer/winter operation, additional tank, etc.).
Device type | Item No. | Operating voltage [V] | Mounting on tank | Tank height |
Tank electrode 30-110 K-FL | 5551 | 12 and 24 | Top side | 30 - 110 |
Test mark: | CE, E-test (EMC/vehicle directive) | |||
Scope of delivery : | 2 sealing rings, union nut PG 29, flexible cable probe, tank wall bushing, stainless steel arrester, fixing screws, operating instructions |