- Product description
- 2 completely separate and independent charging units in one device
- Charging programmes no. 1, 2, 3 and 5 (gel, AGM, acid, start) adjustable to battery type for each charging unit
- Battery capacity can be set 4 times per charging section (16 charging programmes in total)
- Outstanding charging technology
- Signalling output (MA) +86 for engine start inhibit when connected to the vehicle power supply
- Automatic battery regeneration for long downtimes (twice a week)
- Compensation of voltage losses on the charging cables for exact compliance with the charging voltages
- Disconnection of the batteries in the event of mains failure, overheating, incorrect behaviour (safety switch per charging output)
- Electronics protected against moisture
- The charging voltages are free of peaks and regulated to prevent overcharging
- Fully automatic continuous operation for constant operational readiness of the batteries
- Precise battery temperature compensation, temperature sensor included in the scope of delivery
- Intelligent microprocessor control takes into account the simultaneous co-supply of consumers on the battery
- Inputs for voltage sensor cables, optionally usable with extra-long charging cables or with external lossy diode charging current distributors
Optional accessories:
- Remote control S (Art. 2075)
- Remote operating display IP67 (Art. 2081)
- Charger State Monitor IP67 (Art. 2082)
Technical data
Charging power in [V]/[A] | 12 / 15 / 30 |
Nominal voltage (AC) in [V] | 230 |
Operating voltage range (AC) in [V] | 190 - 265 (full charging capacity) |
Power consumption (AC) in max. [W] | 720 |
Sinusoidal power factor correction (CosPhi = 1) | Yes |
Nominal battery voltage (DC) in [V] | 12 |
Battery capacity in [Ah] | 36 - 170 / 75 - 350 |
Charging current in [A] | 15 / 30 |
Auxiliary charging output "S" in [A] | - |
Charging characteristic | IU1oU2 |
Voltage limitation for all charging types/programmes [V] | 15 |
Voltage ripple in [mV] rms | < 50 |
Number of charging outputs | 2 |
Device installation position | any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | I / IP 21 |
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections | 305 x 90 x 265 |
Weight in [g] | 3700 |
Standards (CE) | EN 60335-2-29 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: Mains cable, 2 temperature sensors, operating instructions |
Safety instructions and warnings
Safety instructions for Votronic Automatic Charger VAC 1215/30 Duo without emergency start function
CAUTION: Before installing the appliance or carrying out maintenance work, please read the instructions and safety information carefully.
WARNING: The appliance may only be installed and serviced by trained specialists.
WARNING: Before connecting the appliance, check that the voltage and frequency of the mains connection match the specifications on the appliance's rating plate.
WARNING: The appliance must not be operated near water or moisture.
WARNING: The appliance is intended for use in closed rooms.
WARNING: Do not use the appliance in potentially explosive atmospheres.
WARNING: Only use the battery type and size recommended by the manufacturer.
WARNING: The device must not be operated in the vicinity of flammable materials.
WARNING: Do not overcharge the battery as this may damage the battery and the appliance.
WARNING: Do not use the appliance if the mains cable or plug is damaged.
Manufacturer contact information
Manufacturer Contact
VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach
https://www.votronic.de/kontakt/