- Product description
- Media & Downloads
- Charging programmes no. 1, 2 and 4 (gel, AGM, acid) adjustable to battery type
- Outstanding charging technology
- Charging voltages are free of peaks and regulated to exclude overcharging
- Fully automatic continuous operation for batteries always ready for use
- Precise battery temperature compensation (temperature sensor art. no. 2001 required)
- Separate auxiliary charge output "S" for support and maintenance charging of the vehicle starter battery, max. 2A
- Automatic battery regeneration during long idle periods (twice a week)
- Compensation of voltage losses on the charging cables for exact compliance with the charging voltages
- Intelligent microprocessor control takes into account the simultaneous supply of loads to the battery
- Disconnection of the batteries in case of mains failure, overheating, malfunction (safety switch per charging output)
- Silent-run function adjustable (night setback)
- Battery capacity can be set 4 times (total of 12 charging programmes)
- Inputs for voltage sensor (sense) lines, optionally usable with overlong charging lines and/or external, lossy diode charging current distributors
- Mains/charging power can be reduced in case of low-power or limited mains supply, e.g. weakly fused shore power, generator operation, etc. (power limit function)
Optional accessories:
- Remote control S (art. 2075)
- Remote operating display IP67 (item 2081)
- Charger State Monitor IP67 (Art. 2082)
- Temperature sensor 825 (art. 2001)
Charging power in [V]/[A] | 24 / 40 |
Rated voltage (AC) in [V] | 230 |
Operating voltage range (AC) in [V] | 190 - 265 (full charging capacity) |
Power consumption (AC) in max. [W] | 1380 |
Sinusoidal power factor correction (CosPhi = 1) | yes |
Nominal battery voltage (DC) in [V] | 24 |
Battery capacity in [Ah] | 75 - 440 |
Charging current in [A] | 40 |
Auxiliary charging output "S" in [A] | 2 |
Charging characteristic | IU1oU2 |
Voltage limitation for all charging types/programmes [V] | 30 |
Voltage ripple in [mV] rms | < 80 |
Number of charging outputs | 1 + S |
Device installation position | any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | I / IP 21 |
Dimensions in [mm] - Dimensions incl. mounting flange/feet, without connections | 333 x 262 x 92 |
Weight in [g] | 3.900 |
Standards (CE) | EN 60335-2-29 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: mains cable, operating instructions |