Votronic Automatic Charger Pb 2425 SMT 3B
Votronic Automatic Charger Pb 2425 SMT 3B

Votronic Automatic Charger Pb 2425 SMT 3B

Article no.: 116055A
Manufacturer: Votronic

Offer is exclusively for commercial customers. Prices are only visible after login.

  • Product description
  • Media & Downloads
  • Charging programmes no. 1, 2 and 4 (gel, AGM, acid) adjustable to battery type
  • The charging voltage is free of peaks and regulated in such a way that overcharging of the batteries is excluded.
  • Fully automatic continuous operation: The charger can be permanently connected to the battery and keeps it fully charged. In case of mains failure, the batteries are not discharged (disconnected by safety switch).
  • Lead-acid battery regeneration twice a week during long periods of inactivity to prevent harmful acid stratification.
  • Parallel? and buffer? operation: In case of simultaneous consumption, the battery continues to be charged or kept full. The charger automatically calculates and monitors the adjustment of the charging times.
  • Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short-circuit, polarity reversal, faulty operation and battery reverse discharge by electronic cut-off up to complete disconnection of charger and battery by built-in safety switches.
  • Connection for battery temperature sensor (accessory temperature sensor 825, art. no. 2001): For lead batteries (acid, gel, AGM), the charging voltage is automatically adapted to the battery temperature, resulting in a better full charge of the weaker battery in cold weather, and in summer temperatures, unnecessary battery gassing and thus battery stress is avoided.
  • Silent Run function: noise-optimised operation at the touch of a button (night operation).
  • Power supply function: Enables consumers to be supplied without battery (e.g. battery change).
  • Charging cable compensation: Voltage losses on the charging cables are automatically compensated.
  • Built-in on-board power supply filter: Problem-free parallel operation with solar systems, wind? and petrol generators, dynamos etc. on one battery.
  • Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, ?gel, ?AGM) battery up to 8 V, then powerful support of the battery with consumers that may still be switched on.
  • Disconnection of the batteries in case of mains failure, overheating, malfunction (safety switch for each charging output).
  • Separate secondary charging output "S" for support and maintenance charging of the vehicle starter battery.
  • Built-in charging current distributor with 2 main charging outputs, each with max. current and power capacity
  • Charging current distributor optionally switchable to separate charging programme for starter battery
  • Starter battery is also charged with full charging current if required (short vehicle service life)
  • Battery capacity can be set 4 times (total of 12 charging programmes)
  • Inputs for voltage sensor (sense) cables, optionally usable with overlong charging cables and/or external, lossy diode charging current distributors
  • Mains/charging power can be reduced in case of low-power or limited mains supply, e.g. weakly fused shore power, generator operation, etc. (power limit function)

Optional accessories:

  • Remote control S (art. 2075)
  • Remote operating display IP67 (item 2081)
  • Charger State Monitor IP67 (Art. 2082)
  • Temperature sensor 825 (art. 2001)
Charging power in [V]/[A]24 / 25
Rated voltage (AC) in [V]230
Operating voltage range (AC) in [V]190 - 265 (full charging capacity)
Power consumption (AC) in max. [W]830
Sinusoidal power factor correction (CosPhi = 1)Yes
Nominal battery voltage (DC) in [V]24
Battery capacity in [Ah]46 - 290
Charging current in [A]25
Auxiliary charging output "S" in [A]4
Charging characteristicIU1oU2
Voltage limitation for all charging types/programmes [V]30
Voltage ripple in [mV] rms< 80
Number of charging outputs2 + S
Device installation positionany
Temperature range [°C]-20 to +45
Degree/class of protectionI / IP 21
Dimensions in [mm] - Dimensions incl. mounting flange/feet, without connections330 x 139 x 74
Weight in [g]2.400
Standards (CE)EN 60335-2-29
Ambient conditions, humidity: max. 95% room humidity, non-condensing
Scope of delivery: mains cable, operating instructions