- Product description
- Media & Downloads
- Charging programmes no. 1, 2 and 4 (gel, AGM, acid) adjustable to battery type
- The charging voltage is free of peaks and regulated in such a way that overcharging of the batteries is excluded.
- Fully automatic continuous operation: The charger can be permanently connected to the battery and keeps it fully charged. In case of mains failure, the batteries are not discharged (disconnected by safety switch).
- Lead-acid battery regeneration twice a week during long periods of inactivity to prevent harmful acid stratification.
- Parallel? and buffer? operation: In case of simultaneous consumption, the battery continues to be charged or kept full. The charger automatically calculates and monitors the adjustment of the charging times.
- Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short-circuit, polarity reversal, faulty operation and battery reverse discharge by electronic cut-off up to complete disconnection of charger and battery by built-in safety switches.
- Connection for battery temperature sensor (accessory temperature sensor 825, art. no. 2001): For lead batteries (acid, gel, AGM), the charging voltage is automatically adapted to the battery temperature, resulting in a better full charge of the weaker battery in cold weather, and in summer temperatures, unnecessary battery gassing and thus battery stress is avoided.
- Silent Run function: noise-optimised operation at the touch of a button (night operation).
- Power supply function: Enables consumers to be supplied without battery (e.g. battery change).
- Charging cable compensation: Voltage losses on the charging cables are automatically compensated.
- Built-in on-board power supply filter: Problem-free parallel operation with solar systems, wind? and petrol generators, dynamos etc. on one battery.
- Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, ?gel, ?AGM) battery up to 8 V, then powerful support of the battery with consumers that may still be switched on.
- Disconnection of the batteries in case of mains failure, overheating, malfunction (safety switch for each charging output).
- Separate secondary charging output "S" for support and maintenance charging of the vehicle starter battery.
- Built-in charging current distributor with 2 main charging outputs, each with max. current and power capacity
- Charging current distributor optionally switchable to separate charging programme for starter battery
- Starter battery is also charged with full charging current if required (short vehicle service life)
- Battery capacity can be set 4 times (total of 12 charging programmes)
- Inputs for voltage sensor (sense) cables, optionally usable with overlong charging cables and/or external, lossy diode charging current distributors
- Mains/charging power can be reduced in case of low-power or limited mains supply, e.g. weakly fused shore power, generator operation, etc. (power limit function)
Optional accessories:
- Remote control S (art. 2075)
- Remote operating display IP67 (item 2081)
- Charger State Monitor IP67 (Art. 2082)
- Temperature sensor 825 (art. 2001)
Charging power in [V]/[A] | 24 / 25 |
Rated voltage (AC) in [V] | 230 |
Operating voltage range (AC) in [V] | 190 - 265 (full charging capacity) |
Power consumption (AC) in max. [W] | 830 |
Sinusoidal power factor correction (CosPhi = 1) | Yes |
Nominal battery voltage (DC) in [V] | 24 |
Battery capacity in [Ah] | 46 - 290 |
Charging current in [A] | 25 |
Auxiliary charging output "S" in [A] | 4 |
Charging characteristic | IU1oU2 |
Voltage limitation for all charging types/programmes [V] | 30 |
Voltage ripple in [mV] rms | < 80 |
Number of charging outputs | 2 + S |
Device installation position | any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | I / IP 21 |
Dimensions in [mm] - Dimensions incl. mounting flange/feet, without connections | 330 x 139 x 74 |
Weight in [g] | 2.400 |
Standards (CE) | EN 60335-2-29 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: mains cable, operating instructions |