Votronic Battery Charger VAC 60-15/30 Triple CI
Votronic Battery Charger VAC 60-15/30 Triple CI

Votronic Battery Charger VAC 60-15/30 Triple CI

Article no.: 116122A
Manufacturer: Votronic

Offer is exclusively for commercial customers. Prices are only visible after login.

  • Product description
  • The full charging power in the universal wide range of 110 V AC - 230 V AC without switching is available worldwide even with large deviations in the mains supply (undervoltage/overvoltage, sine wave, frequency).
  • Powerful charging of the on-board battery and supply of the 12 V consumers from the mains.
  • Charging current distributor with 2nd charging branch 12 V/10-15 A for charging the starter battery and supplying the 12 V vehicle consumers from the mains - with charge retention during long downtimes.
  • Thanks to the multi-stage long-term charging characteristic curves, the device can be permanently connected to the mains (use, winter break) and keep the batteries fit.

Charging converter, "B2B" operation, mobile operation from dynamo and starter battery (battery to battery):

  • The powerful charging converter (booster) enables the on-board battery to be fully charged while driving.
  • It increases/reduces the voltage to the required level in order to charge the on-board battery precisely with the optimum charging characteristic.
  • It fully compensates for line losses and significant voltage fluctuations in the dynamo, such as those that occur constantly in Euro 6 vehicles.
  • The 12V consumers supplied with power are protected against overvoltage and voltage fluctuations.

Pulser operation, training for the on-board battery during charging breaks when no charging source is available:

  • Battery training protects the unused (lead-acid) battery from rapid ageing and failure due to sulphation during longer breaks or seasonal operation.

Other device features:

  • The charging voltage is free of peaks and regulated in such a way that overcharging of the batteries is ruled out.
  • Fully automatic continuous operation: The charger can be permanently connected to the batteries and keeps them fully charged. If no charging source is available (mains failure, engine stop), the batteries are not discharged.
  • Parallel and buffer operation: The battery continues to be charged or is kept fully charged during simultaneous consumption. The charger automatically calculates and monitors the adjustment of the charging times.
  • Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short circuit, misbehaviour and battery back-discharge through electronic cut-off up to complete disconnection of charger and battery.
  • Power supply function: Enables consumers to be supplied without a battery (e.g. when changing the battery).
  • Built-in on-board mains filter: Problem-free parallel operation with other charging sources (wind, motor and fuel generators) on one battery.
  • Charging cable compensation: Voltage losses on the charging cables are automatically compensated for.
  • Connection for battery temperature sensor (included): With lead batteries (acid, gel, AGM), the charging voltage is automatically adjusted to the battery temperature, resulting in better full charging of the weaker battery in cold weather and avoiding unnecessary battery gassing in summer temperatures. LiFePO4 batteries: Battery protection at high and especially at low temperatures < 0°C. Highly recommended if the battery temperature can fall below 0°C during operation.
  • Automatic lead battery regeneration twice a week during downtimes to prevent harmful acid stratification.
  • Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support for the battery if consumers are still switched on.
  • Plug-in connection for optional LCD Charge Control S

Optional accessory:

  • LCD-Charge Control S(item no. 1247)
  • ByPass relay 12V / 200A (item no. 2201)
  • Changeover relay 12V / 60A (item no. 2202)

Technical data

Mains operation
Rated operating voltage (AC) in [V]110 to 230 / 45 - 65 Hz worldwide
Operating voltage range (AC) in [V]90 - 270 (full charging capacity)
Max. Power consumption (AC) in [W]780
Charging power on-board/starter battery max. [A]45,0 / 15,0
Switching output for engine start interlockyes
Power limit functionyes
12 V / 12 V B2B charging converter operation
Charging power on-board battery max. [A]60
Automatic activation D+ / ignitionyes
Starter battery/LiMa Voltage range (Euro 6) in [V] / max. current [A]10,5 - 16,5 / 63
Limit II max. current limitation (adjustable) in [A]65
Starter battery
Nominal voltage [V] / min. capacity [Ah] recommended12 / > 100
On-board battery, IU1oU2oU3
Nominal voltage lead / LiFePO4 [V]12 / 12,8 - 13,3
Battery capacity, adjustable [Ah]90 - 560
Device installation positionAny
Temperature range [°C]-20 to +45
Degree/class of protectionIP 21
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections217 x 85 x 250
Weight [g]2.900
Ambient conditions, humidity: max. 95% room humidity, non-condensing
Scope of delivery: Mains cable, 1 temperature sensor, operating instructions

Safety instructions and warnings

Safety instructions for Votronic Battery Charger VAC 60-15/30 Triple CI

General safety instructions:

  • The Votronic Battery Charger VAC 60-15/30 Triple CI may only be used for its intended purpose.
  • Only battery types authorised by the manufacturer may be connected.
  • No modifications may be made to the device.
  • The device must not be operated in the vicinity of explosive gases.
  • The device must not be operated under water or in a damp environment.
  • The device must not be operated near heat sources.

Operating instructions:

  • The appliance must be set up on a stable, level surface.
  • Sufficient distance from other appliances must be ensured to allow adequate ventilation.
  • The appliance must be protected from moisture and dust.
  • The appliance may only be operated by trained personnel.
  • The appliance must be protected from power failures and voltage fluctuations.
  • The appliance must be disconnected from the power supply before maintenance work.
  • Care must be taken to ensure that the appliance is not overloaded.
  • The appliance must be serviced regularly to ensure a long service life.
Manufacturer contact information

Manufacturer Contact

VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach

https://www.votronic.de/kontakt/

Subscribe to our newsletter
Our newsletter is free of charge and can be canceled at any time here or in your customer account.