- Product description
- Technical details
Mains operation, standby operation at the external socket from the mains:
- The full charging power in the universal wide range of 110 V AC - 230 V AC without changeover is available worldwide even in the event of major deviations in the mains supply (undervoltage/overvoltage, sinusoidal shape, frequency).
- Powerful charging of the on-board battery and supply of the 12 V consumers from the mains.
- Charging current distributor with 2nd charging branch 12 V/10-15 A for charging the starter battery and supplying the 12 V vehicle consumers from the mains - with charge retention during long idle periods.
- Thanks to the multi-stage long-term charging characteristics, the unit can be permanently connected to the mains (operational, winter break) and keep the batteries fit.
Charge converter, "B2B" operation, mobile operation from dynamo and starter battery (battery to battery):
- The powerful charge converter (booster) enables the on-board battery to be fully charged while driving.
- It increases/decreases the voltage to the necessary level to precisely charge the on-board battery with the optimal charging characteristic.
- It fully compensates for line losses and significant voltage fluctuations of the dynamo, such as those that constantly occur in Euro 6 vehicles.
- The supplied 12V consumers are protected against overvoltage and voltage fluctuations.
Pulser operation, training for the on-board battery during charging breaks when no charging source is available:
- Battery training protects the unused (lead) battery from rapid ageing and failure due to sulphation during longer breaks or seasonal operation.
Other unit features:
- The charging voltage is free of peaks and regulated in such a way that overcharging of the batteries is excluded.
- Fully automatic continuous operation: The charger can be permanently connected to the batteries and keeps them fully charged. If no charging source is available (mains failure, engine stop), the batteries are not discharged.
- Parallel and buffer operation: In case of simultaneous consumption, the battery continues to be charged or kept full. The charger automatically calculates and monitors the adjustment of the charging times.
- Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short-circuit, malfunction and battery back-discharge by electronic cut-off up to complete disconnection of charger and battery.
- Power supply function: Enables consumers to be supplied without a battery (e.g. when changing batteries).
- Built-in on-board power supply filter: Problem-free parallel operation with other charging sources (wind, motor and fuel generators) on one battery.
- Charging cable compensation: Voltage losses on the charging cables are automatically compensated.
- Connection for battery temperature sensor (included in delivery): For lead batteries (acid, gel, AGM), the charging voltage is automatically adapted to the battery temperature, resulting in better full charging of the weaker battery in cold weather and avoiding unnecessary battery gassing in summer temperatures. LiFePO4 batteries: Battery protection at high and especially at low temperatures < 0°C. Highly recommended if the battery temperature can drop below 0°C during operation.
- Lead-acid battery regeneration automatically twice a week during standstill periods against harmful acid stratification.
- Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support of the battery with any consumers still switched on.
- Plug-in connection for optional LCD Charge Control S.
Optional accessory:
- LCD Charge Control S(art. no. 1247)
- ByPass relay 12V / 200A (art. no. 2201)
- Change-over relay 12V / 60A (art. no. 2202)
Mains operation | |
Rated operating voltage (AC) in [V] | 110 to 230 / 45 - 65 Hz worldwide |
Operating voltage range (AC) in [V] | 90 - 270 (full charging capacity) |
Max. Power consumption (AC) in [W] | 610 |
Charging power on-board/starter battery max. [A] | 35,0 / 10,0 |
Switching output for engine start disable | yes |
Power limit function | yes |
12 V / 12 V B2B charging converter operation | |
Charging capacity on-board battery max. [A] | 45 |
Automatic activation D+ / ignition | yes |
Starter battery/LiMa Voltage range (Euro 6) in [V] / max. current [A] | 10,5 - 16,5 / 63 |
Limit II max. current limitation (adjustable) in [A] | 48 |
Starter battery | |
Nominal voltage [V] / min. capacity [Ah] recommended | 12 / > 80 |
On-board battery, IU1oU2oU3 | |
Nominal voltage lead / LiFePO4 [V] | 12 / 12,8 - 13,3 |
Battery capacity, adjustable [Ah] | 68 - 420 |
Device installation position | Any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | IP 21 |
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections | 217 x 85 x 250 |
Weight [g] | 2.800 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: Mains cable, 1 temperature sensor, operating instructions |