- Product description
With the inverters you can operate household appliances that require 230 V/120 V alternating current with leisure or car batteries with 12 V, 24 V or 48 V direct current.
Models:250 VA, 375 VA, 500 VA, 800 VA, 1200 VA
Proven reliability
The full bridge and toroidal transformer topology has proven itself over many years. The inverters are short-circuit-proof and protected against overheating, whether due to overload or high ambient temperature.
ECO mode
In ECO mode, the inverter switches to standby mode when the load falls below a preset value (minimum load: 15 W). In standby mode, the inverter switches on for a short time (adjustable, default: every 2.5 seconds). If the load exceeds a preset value, the inverter remains switched on.
High starting power
Required for starting loads such as power converters for LED lamps, halogen lamps or power tools.
Technical data
Power [W]: 1000
Output [VA]: 1200
Peak power [W]: 2200
Max. efficiency [%]: 91
Input voltage range DC [V]: 18.4 - 34
DC input voltage [V]: 24
Low-voltage load disconnection [V]: 18.6
Low-voltage load reconnection [V]: 21.8
Feed-in phases: 1
Weight [kg]: 7.4
Dimensions [mm]: 327 x 232 x 117
Communication type: VE.Direct
Product guarantee: 5 years
Safety instructions and warnings
Safety instructions for Victron Energy Phoenix inverter 24/1200 230 V VE.Direct IEC
- Ensure that the inverter is properly earthed to minimise the risk of electric shock. - Only use the mains cable supplied to connect the inverter to the power grid. Check the cable regularly for damage. - Ensure that the inverter does not overheat. Ensure that there is sufficient ventilation and that the inverter is not blocked by other objects. - The inverter should be protected from moisture and water. Therefore, only use it in dry environments. - Switch off the inverter before carrying out maintenance work or cleaning it. Also disconnect it from the power grid to avoid the risk of electric shock. - Do not use the inverter in the vicinity of flammable materials or in potentially explosive atmospheres. - Observe the maximum load capacity of the inverter. Do not exceed the specified power limit in order to avoid damage or malfunctions. - Read the operating instructions carefully before commissioning the inverter and follow all the manufacturer's instructions. Please note that this is a general compilation of safety and operating instructions. For more detailed information and specific instructions, you should consult the manufacturer's website, manufacturer's instructions or other valid sources.Manufacturer contact information