With the inverters you can operate household appliances that require 230 V/120 V alternating current with leisure or car batteries with 12 V, 24 V or 48 V direct current.

Models:250 VA, 375 VA, 500 VA, 800 VA, 1200 VA

Proven reliability

The full bridge and toroidal transformer topology has proven itself over many years. The inverters are short-circuit-proof and protected against overheating, whether due to overload or high ambient temperature.

ECO mode

In ECO mode, the inverter switches to standby mode when the load falls below a preset value (minimum load: 15 W). In standby mode, the inverter switches on for a short time (adjustable, default: every 2.5 seconds). If the load exceeds a preset value, the inverter remains switched on.

High starting power

Required for starting loads such as power converters for LED lamps, halogen lamps or power tools.

Technical data

Power [W]: 300

Output [VA]: 375

Peak power [W]: 700

Max. efficiency [%]: 89

Input voltage range DC [V]: 18.4 - 34

DC input voltage [V]: 24

Low-voltage load disconnection [V]: 18.6

Low-voltage load reconnection [V]: 21.8

Feed-in phases: 1

Weight [kg]: 3

Dimensions [mm]: 260 x 165 x 86

Communication type: VE.Direct

Product guarantee: 5 years

Safety instructions and warnings

Safety instructions for Victron Energy Phoenix inverter 24/375 230 V VE.Direct SCHUKO:

1. the inverter may only be operated by trained and qualified specialist personnel.

2. before installing and maintaining the inverter, it is essential to disconnect all voltages from the device.

3. the inverter must not be installed near flammable materials.

4. use only the cables and connections recommended by the manufacturer to connect the inverter.

5. ensure that the ventilation openings of the inverter are not blocked.

6. the inverter must be protected from moisture and water.

7. if faults or unusual noises occur, the inverter must be switched off immediately and checked by a specialist.

8 Opening the inverter is strictly prohibited and can lead to serious injury.

9. the inverter must not be set up near children and must be protected against unauthorised access.

Manufacturer contact information

Contact manufacturer

Victron Energy B.V.

De Paal 35

1351 JG Almere

The Netherlands

sales@victronenergy.com

Subscribe to our newsletter
Our newsletter is free of charge and can be canceled at any time here or in your customer account.