- Product description
Pure sine wave output, high peak power and high efficiency. Combined high-frequency and mains frequency technologies provide the best of both worlds.
SinusMax - Superior technology
The Phoenix inverters were developed for professional use and are suitable for a wide range of applications. The design criteria were to develop a true sine wave inverter with optimised efficiency without compromising on performance. The result is a high quality product with compact dimensions, low weight and the ability to power any load with ease.
Parallel and 3-phase operation
Up to 6 Phoenix inverters can be operated in parallel to achieve a higher output power. For example, six 24 V 5000 VA devices deliver 24 kW / 30 kVA output power. Operation in 3-phase configuration is also possible.
Models:3000VA - 5000VA
Technical data
Power [W]: 2400
Output [VA]: 3000
Peak power [W]: 6000
Max. efficiency [%]: 94
Input voltage range DC [V]: 19 - 33
Input voltage DC [V]: 24
Feed-in phases: 1
Weight [kg]: 18
Dimensions [mm]: 258 x 362 x 218
Communication type: VE.Bus; VE.Net
Product guarantee: 5 years
Safety instructions and warnings
Safety instructions for Victron Energy Phoenix inverter 24/3000 230 V VE.Bus
Observe the following safety and operating instructions when handling the Victron Energy Phoenix inverter 24/3000 230 V VE.Bus:
- The inverter should only be installed and commissioned by qualified personnel.
- The inverter must be connected to an earthed socket.
- It is important that all connections are correctly and firmly screwed in.
- Keep the inverter away from water and moisture to avoid short circuits and damage.
- Only use accessories and spare parts recommended by the manufacturer and follow all instructions for installation and use.
- Avoid operating the inverter in extreme temperatures or in dusty environments.
- Ensure that the inverter is always properly ventilated to avoid overheating and possible failures.
- The inverter should be protected from shocks and vibrations.
- Observe the maximum permissible output of the inverter and ensure that no overloading occurs.
- In the event of malfunctions or problems, the inverter should be switched off immediately and checked by a specialist.
Manufacturer contact information
Contact manufacturer
Victron Energy B.V.
De Paal 35
1351 JG Almere
The Netherlands
sales@victronenergy.com