- Product description
Mains operation, standby operation at the external socket from the mains:
- The full charging power in the universal wide range of 110 V AC - 230 V AC without switching is available worldwide even with large deviations in the mains supply (undervoltage/overvoltage, sine wave, frequency).
- Powerful charging of the on-board battery and supply of the 12 V consumers from the mains.
- Auxiliary charging branch 12 V/4-5 A for supporting and maintaining the charge of the vehicle (lead) starter battery during long downtimes.
- Thanks to the long-term charging characteristics, the device can be permanently connected to the mains (use, winter break).
Charging converter, "B2B" operation, mobile operation from dynamo and starter battery (battery to battery):
- The powerful charging converter (booster) enables the on-board battery to be fully charged while travelling.
- It increases/reduces the voltage to the required level in order to charge the on-board battery precisely with the optimum charging characteristic.
- It fully compensates for line losses and significant voltage fluctuations in the dynamo, such as those that constantly occur in Euro 6 vehicles.
- The supplied 12 V consumers are protected against overvoltage and voltage fluctuations.
Solar operation, "MPP" (Maximum Power Point):
- With MPP technology, the controller constantly and automatically determines the maximum power output (MPP) of the solar modules several times per second. The additional charging current gain of 10 % to 30 % ensures shorter charging times and the best possible power utilisation of the solar system.
- Auxiliary charging branch for support charging and charge retention of the vehicle starter battery during long downtimes.
- AES" switching output, automatically switches refrigerators with "AES" (Automatic Energy Selector, Electrolux / Dometic) from gas to 12 V operation when there is a permanent surplus of solar power.
Pulser operation, training for the on-board battery during charging breaks when no charging source is available:
- Battery training protects the unused (lead-acid) battery from rapid ageing and failure due to sulphation during wintering, seasonal operation or longer downtimes.
Other device features:
- The charging voltage is free of peaks and regulated in such a way that overcharging of the batteries is ruled out.
- Fully automatic continuous operation: The charger can be permanently connected to the batteries and keeps them fully charged. If no charging source is available (power failure, engine stop, night), the batteries are not discharged.
- Parallel and buffer operation: The battery continues to be charged or is kept fully charged if there is simultaneous consumption. The charger automatically calculates and monitors the adjustment of the charging times.
- Monitoring-free charging: Multiple protection against overload, overheating, overvoltage, short circuit, misbehaviour and battery back-discharge through electronic cut-off up to complete disconnection of charger and battery.
- Power supply function: Enables consumers to be supplied without a battery (e.g. when changing the battery).
- Built-in on-board mains filter: Problem-free parallel operation with other charging sources (wind, motor and fuel generators) on one battery.
- Charging cable compensation: Voltage losses on the charging cables are automatically compensated for.
- Connection for battery temperature sensor (included): With lead batteries (acid, gel, AGM), the charging voltage is automatically adjusted to the battery temperature, resulting in better full charging of the weaker battery in cold weather and avoiding unnecessary battery gassing in summer temperatures. LiFePO4 batteries: Battery protection at high and especially at low temperatures < 0°C. Highly recommended if the battery temperature can fall below 0°C during operation.
- Automatic lead battery regeneration twice a week during downtimes to prevent harmful acid stratification.
- Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support for the battery if consumers are still switched on.
- Plug-in connection for optional LCD Charge Control S
Optional accessory:
- LCD-Charge Control S(item no. 1247)
- ByPass relay 12V / 200A (item no. 2201)
- Changeover relay 12V / 60A (item no. 2202)
Technical data
Mains operation | |
Rated operating voltage (AC) in [V] | 110 to 230 / 45 - 65 Hz worldwide |
Operating voltage range (AC) in [V] | 90 - 270 (full charging capacity) |
Max. Power consumption (AC) in [W] | 520 |
Charging power on-board/starter battery max. [A] | 30,0 / 4,0 |
Switching output for engine start disable | yes |
Power limit function | yes |
12 V / 12 V B2B charging converter operation | |
Charging capacity on-board battery max. [A] | 45 |
Automatic activation D+ / ignition | yes |
Starter battery/LiMa Voltage range (Euro 6) in [V] / max. current [A] | 10,5 - 16,0 / 63 |
Limit II max. current limitation (adjustable) in [A] | 48 |
MPP solar charge controller operation | |
Solar module output (Pmax) in [Wp] | 50 - 350 |
Solar module current max. [A] | 21,0 |
Solar module voltage (Voc) max. [V] | 36 |
Charging current on-board / starter battery max. [A] | 25,5 / 5,0 |
Switching output AES refrigerator | Yes |
Starter battery | |
Nominal voltage [V] / capacity min. [Ah] recommended | 12 / > 80 |
On-board battery, IU1oU2oU3 | |
Nominal voltage lead / LiFePO4 [V] | 12 / 12,0 - 13,3 |
Battery capacity, adjustable [Ah] | 68 - 420 |
Device installation position | Any |
Temperature range [°C] | -20 to +45 |
Degree/class of protection | IP 21 |
Dimensions (WxHxD) in [mm] - Dimensions incl. mounting flanges, without connections | 217 x 85 x 250 |
Weight [g] | 2.850 |
Ambient conditions, humidity: max. 95% room humidity, non-condensing | |
Scope of delivery: Mains cable, 1 temperature sensor, operating instructions |
Safety instructions and warnings
Safety instructions for Votronic Battery Charger VBCS 45/30/350 Triple CI:
1. general safety instructions:
- Read the operating instructions carefully before using the device.
- Do not use the device if it is damaged or shows signs of wear.
- Only use the device in accordance with the manufacturer's instructions.
- Only connect the appliance to a suitable power source.
- Keep the appliance out of the reach of children and pets.
- Avoid contact with water or other liquids.
- Switch off the appliance before carrying out maintenance work.
- Do not use the appliance near flammable materials.
- Keep the appliance away from heat sources.
- Do not overload the appliance and do not use unauthorised adapters.
2. operating instructions:
- Ensure that the batteries are connected correctly.
- Pay attention to the correct polarity when connecting the batteries.
- Only use the device for its intended purpose.
- Observe the specified capacity and voltage values for the batteries.
- Check the charge status of the batteries regularly.
- Observe the specified charging times for optimum performance.
- Keep the device clean and free from dirt.
- Protect the device from shocks or strong vibrations.
- Do not leave the device unattended during the charging process.
- Follow the manufacturer's specific instructions for operation.
Please note that this is an overview of the safety and operating instructions and does not cover all details. Always consult the official manufacturer's documents for complete and up-to-date information.
Manufacturer contact information
Manufacturer Contact
VOTRONIC Elektronik-Systeme GmbH
Johann-Friedrich-Diehm-Str. 2
36341 Lauterbach
https://www.votronic.de/kontakt/